2 Installation
2.10.1 Installation of Water and air unit
Continued
Item in figure
B
Shop water supply
Use this procedure to connect the Water and Air unit to the shop water supply.
1
2
Shop compressed air supply
Use this procedure to connect the Water and Air unit to the shop compressed air
supply.
1
Water drain connection, One water return
Use this procedure to connect the water drain connection with one water return,
to the Water and Air unit.
1
2
Continues on next page
128
Connect to:
Shop water drain
Note! In case of a second water
return, the water drain connection
is moved to the outside of the
mounting plate!
Action
Route the water supply hose through the
upper hole in the mounting plate.
Connect the hose to the fitting with a G½"
thread on the solenoid valve (A).
CAUTION
Do not tighten the brass couplings for water
and air with excessive force.
Action
Connect the air hose to the fitting with a
G½" thread on the air shut off valve (C).
CAUTION
Do not tighten the brass couplings for water
and air with excessive force.
Action
Route the water drain hose through the
lower hole in the mounting plate.
Connect the hose to the fitting with a G½"
thread on the check-valve.
CAUTION
Do not tighten the brass couplings for water
and air with excessive force.
© Copyright 2015-2017 ABB. All rights reserved.
Function:
Note
Tightening torque, brass couplings 1/2":
31 Nm
Tightening torque, brass couplings 3/8":
17 Nm
Note
Tightening torque, brass couplings 1/2":
31 Nm
Tightening torque, brass couplings 3/8":
17 Nm
Note
xx0600003348
B: Water drain connection, one
water return