2.10 Water & Air unit

2.10.1 Installation of Water and air unit

Location of the Water and Air unit
The Water and Air unit is located on top of the robot base.
General technical data
The table below shows technical data of the water and air pressure:
Parameter
Water operating pressure
Air operating pressure
The table below shows technical data for water and air quality:
Parameter
Water quality
Air quality
Product manual - DressPack/SpotPack IRB 8700
3HAC055802-001 Revision: B
© Copyright 2015-2017 ABB. All rights reserved.
2.10.1 Installation of Water and air unit
Value
Max. 0.6 MPa / 87 PSI
Max. 1.0 MPa / 145 PSI
Value
Normal filtered industrial water quality, 80 to
100 mesh.
Use clean air.
When there is excessive condensate, install
a device that will eliminate water, such as a
dryer or water separator (Drain Catch) on the
inlet side of the air filter.