Replacement Of Door Fan Unit - ABB IRC5P Product Manual

Control cabinet
Table of Contents

Advertisement

7.4 Replacement of Door Fan Unit

Location
References
Tools and Items
Removal
Product Manual, Control Cabinet IRC5P
The Door Fan Unit is used for internal circulation in the controller. The unit is
located at the lower end of the controller front door as shown below.
Figure 69 Door fan unit
1
Door Fan Unit
2
Cable strap
3
Connector
4
Upper and lower attachment screws
– No references
– Hand tools
The procedure describes how to remove the fan unit on the front door.
No repair work must be performed on the robot before the safety
WARNING!
regulations in
'Safety'
1.
Turn the electrical disconnect switch 'off' and lock switch in 'off' position.
Make sure that the mains switch is 'off' and locked in 'off' position
WARNING!
before continuing. Also make sure that possible other connected systems are 'off'.
2.
Open controller front door and locate the fan unit (69/1).
3.
Cut cable strap (69/2) securing cable to fan unit.
4.
Disconnect connector (69/3).
3HNA009834-001 en Rev.06
2
1
on page 13 have been read and understood.
7.4 Replacement of Door Fan Unit
4
3
2
7 Repair
4
135

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents