Refitting the protection hose
Use these procedures to refit the protection hose
Refitting the back part protection hose
1
2
3
4
5
Product manual - DressPack/SpotPack IRB 8700
3HAC055802-001 Revision: B
4.2.5 Replacing the protection hose IRBDP SW6 UI and IRBDP MH6 UI LeanID
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Cut the new protection hose, back part to
the length required.
Note
Place the cut on top of a ridge.
Put some cable grease on cables and
hoses on the area where they run through
the protection hose and hose reinforcement
funnel.
Carefully push cables and hoses into the
protection hose.
Tip
1 Cables with large connectors
2 Hoses
3 Cables with small connectors
Make sure that cables and hoses are not
twisted.
© Copyright 2015-2017 ABB. All rights reserved.
Note
A
xx0300000061
Length: 745 mm
Continues on next page
4 Repair
Continued
207