ABB DressPack Product Manual page 172

Table of Contents

Advertisement

4 Repair
4.2.2 Replacing the cable package IRBDP MH LI
Continued
2
3
4
Continues on next page
172
Action
CAUTION
The cable package is sensitive to mechanical
damage. Handle it with care in order to avoid
damaging the cabling or the connectors.
Fit the connection plate. Lock screws with locking
liquid (Loctite 243)
Fasten the Profinet bracket.
© Copyright 2015-2017 ABB. All rights reserved.
Note
xx1500002970
M10x25 A2-7 0 (2 pcs)
xx1500002971
M3x8 A2-70 (4 pcs)
Product manual - DressPack/SpotPack IRB 8700
3HAC055802-001 Revision: B