ABB DressPack Product Manual page 215

Table of Contents

Advertisement

6
7
8
9
10
11
Product manual - DressPack/SpotPack IRB 8700
3HAC055802-001 Revision: B
Action
Connect the Proc 4 hose from the Air supply unit.
CAUTION
Do not tighten the brass couplings for water and air
with excessive force.
Connect the Proc 1 hose from the Air supply unit.
CAUTION
Do not tighten the brass couplings for water and air
with excessive force.
Connect the hose of the compressed air supply of
the workshop.
Turn on the air supply to the Water and Air unit.
Turn on the hand operated air valve on the air sup-
ply circuit.
See if there are any leakages.
© Copyright 2015-2017 ABB. All rights reserved.
4.3.1 Replacement of Air supply circuit
Note
Only if the option Proportional
valve has been selected.
Tightening torque, brass coup-
lings 1/2": 31 Nm
Tightening torque, brass coup-
lings 1/2": 31 Nm
The hoses at the robot will be
compressed.
Tighten if there is leakage.
4 Repair
Continued
215

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spotpack irb 8700

Table of Contents