Parameter Setting; Station Parameters - WAGO -I/O-SYSTEM 750 Technical Description, Installation And Configuration

Profinet io modular i/o-system fieldbus coupler
Hide thumbs Also See for WAGO-I/O-SYSTEM 750:
Table of Contents

Advertisement

56 •
PROFINET IO 750-340
I/O Device Configuration
3.1.3.3

Parameter Setting

3.1.3.3.1

Station Parameters

The parameters of the station substitute are used to set the overall settings of
the PROFINET IO node. Some of the settings are used in the modules as
default settings and can be optionally overwritten within the module
configuration.
Parameter
Restart the internal
bus after a fault
Internal Data Bus
Extension
Message external
module / channel
fault
Process value
display
Setting
POWER ON RESET*)
AUTORESET
EEPROM setting*)
not used
used
locked
released*)
INTEL (LSB-MSB)
MOTOROLA (MSB-
LSB)*)
Description
Restart of the internal data bus
following a fault, such as, for
example, no end module following
after an interruption of the buscoupler
supply
immediately after overcoming the
internal bus fault
Use of the internal data bus extension
Based upon the settings made in
EEPROM that are made using the
"WAGO Extension Settings" tool.
is excluded
is possible
The external diagnostics information
of all diagnostics capable I/O modules
are
not transferred to the PROFINET
I/O Controller
transferred to the PROFINET
I/O Controller
Word or double word orientated
process data are transfered to the
PROFINET I/O Controller in:
"Little Endian" format
"Big Endian" format
WAGO-I/O-SYSTEM 750