Pwm Module - WAGO -I/O-SYSTEM 750 Technical Description, Installation And Configuration

Profinet io modular i/o-system fieldbus coupler
Hide thumbs Also See for WAGO-I/O-SYSTEM 750:
Table of Contents

Advertisement

204 • I/O Modules
Configuration and Parameter Setting of the Modules
5.3.5.2

PWM Module

PNIO
Module type
2PWM
2PWM, EM
PNIO
Module type
PWM
PWM_RA
EA Type
Module type member
PWM
75x-511
PWM_EM
Length
Bit allocation
[Bit]
7
6
5
2
2
2
Output data channel 0 HB4) (LB5))
4
Output data
channel 0 LB4) (HB5))
Output data
channel 1 HB4) (LB5))
Output data
channel 1 LB4) (HB5))
\ - - - - - - - - - - - - - - Output - - - - - - - - - - - - - - /
PD
6
-
RA
Input date. K. 0 HB4)
(LB5))
Input date K. 0 LB4)
(HB5))
PD
-
RA
Input date K. 1 HB4)
(LB5))
1 LB4)
Input date K.
(HB5))
\ - - - - - - - - - - - - - - Input - - - - - - - - - - - - - - /
PD
6
RW
RA
Output date K. 0 HB4)
(LB5))
Output date K. 0 LB4)
(HB5))
PD
RW
RA
Set counter reading K. 1
HB4) (LB5))
Set counter reading K. 1
LB4) (HB5))
\ - - - - - - - - - - - - - - Output - - - - - - - - - - - - - - /
Inputs
4
3
2
1
0
2
2
2
2
2
Status / Register RES
Channel 0 / Table 0
Register date RD
Tab. 0, HB4) (LB5))
Register date RD
Tab. 0, LB4) (HB5))
Status / Register RES
Channel 1 / Table 1
Register date RD
Tab. 1, HB4) (LB5))
Register date RD
Tab. 1, LB4) (HB5))
Control / Register REQ
Channel 0 / Table 0
Register date WR
Tab. 0, HB4) (LB5))
Register date WR
Tab. 0, LB4) (HB5))
Control / Register REQ
Channel 1 / Table 1
Register date WR
Tab. 1, HB4) (LB5))
Register date WR
Tab. 1, LB4) (HB5))
Instances
PNIO-Data type
Input
Integer 16
-
Unsigned 8
2
Integer 16
Note
2 words (4 byte) are applied in the output
process image of the station proxy (fieldbus
coupler) by fitting the slot with this module
and are assigned to the two output signal
channels of the module using 1 word (2 byte)
each. The quality rating of the bytes are a
result of the selected data format that can be
set channel for channel. This module should
only be used in standard operation (without
article number extension) as no input
information can be provided. Two byte
process data qualifiers (IOPS, IOCS) are
managed in the direction of the I/O controller
in the cyclic PROFINET IO telegram for
these modules.
3 words (6 byte) are applied in the output
process image of the station proxy (fieldbus
coupler) and 1 byte and 1 word (2 byte) are
assigned to both signal channels of the
module by fitting the slot with this module.
The quality rating of the bytes within the
word are a result of the selected data format
that can be set channel for channel. Two byte
process data qualifiers (IOPS, IOCS) are
managed in the direction of the I/O controller
in the cyclic PROFINET IO telegram for
these modules.
WAGO-I/O-SYSTEM 750
PROFINET IO
Output
2
2