Channel Digital Input Modules With 1 Bit Diagnostics Status And Confirmation Per Channel - WAGO -I/O-SYSTEM 750 Technical Description, Installation And Configuration

Profinet io modular i/o-system fieldbus coupler
Hide thumbs Also See for WAGO-I/O-SYSTEM 750:
Table of Contents

Advertisement

188 • I/O Modules
Configuration and Parameter Setting of the Modules
5.3.2.9
2-Channel Digital Input Modules with 1 Bit Diagnostics Status and
Confirmation per Channel
PNIO
Module type
2DE(+6 BIT I),
2ACK(+6 BIT O)
2DE(+4 BIT I),
2ACK(+6 BIT O),
DIA in E-PA
2DE(+14 BIT I),
2ACK(+14 BIT O)
2DE(+12 BIT I),
2ACK(+14 BIT O),
DIA in E-PA
2DE(+30 BIT I),
2ACK(+30 BIT O)
2DE(+28 BIT I),
2ACK(+30 BIT O),
DIA in E-PA
* 2DE(-2 BIT I),
2ACK(-2 BIT O)
* 2DE(-4 BIT I),
2ACK(-2 BIT O),
DIA in E-PA
PNIO
Module type
2DE(+6 BIT I),
2ACK(+6 BIT O)
2DE(+14 BIT I),
2ACK(+14 BIT O)
2DE(+30 BIT I),
2ACK(+30 BIT O)
EA Type
Module type member
75x-418
DIO_8
DIO_DIA_8
DIO_16
DIO_DIA_16
DIO_32
DIO_DIA_32
75x-418*
DIO_0
DIO_DIA_0
Length
Bit allocation
[Bit]
7
6
5
2
2
2
2
\ - - - - - - - - - - - - - - Output - - - - - - - - - - - - - - /
2
\ - - - - - - - - - - - - - - Input - - - - - - - - - - - - - - /
Inputs
4
3
2
1
0
2
2
2
2
2
Q1
Q0
E1
E0
Instances
PNIO-Data type
Input
1
Unsigned 8-Bit
field
1
1
Unsigned 16-Bit
field
1
1
Unsigned 32-Bit
field
1
-
-
Note
8, 16 or 32 bits are fitted in the input and
output process image of the station proxy
(fieldbus coupler) by fitting a slot with these
0
1
modules. The bits 2
and 2
in the input area
are assigned with the signal condition of the
physically connected I/O module. The bits
marked green are made available for the
input and / or diagnostics information of the
0
following module slots. The bits 2
are used to confirm diagnostics results in the
2
7
15
output area. The bits 2
to 2
, 2
or 2
marked green are made available for the
output and / or confirmation information of
the following modules. Two byte process
data qualifiers (IOPS, IOCS) are managed
in the transmission direction of the I/O
controller in the cyclic PROFINET IO
telegram for these modules.
WAGO-I/O-SYSTEM 750
PROFINET IO
Output
1
1
1
1
1
1
-
1
and 2
31

Hide quick links:

Advertisement

Table of Contents
loading