178 • I/O Modules
Configuration and Parameter Setting of the Modules
5.3.2.5
4-Channel Digital Output Modules with 1 Bit Diagnostics Status per
Channel
PNIO
Module type
4DA(+4 BIT O)
4DA(+4 BIT I/O),
DIA in E-PA
4DA(+12 BIT O)
4DA(+12 BIT I/O),
DIA in E-PA
4DA(+28 BIT O)
4DA(+28 BIT I/O),
DIA in E-PA
* 4DA(-4 BIT O)
* 4DA(-4 BIT I/O),
DIA in E-PA
PNIO
Module type
4DA(+4 BIT O)
4DA(+12 BIT O)
4DA(+28 BIT O)
4DA(+4 BIT I/O),
DIA in E-PA
4DA(+12 BIT I/O),
DIA in E-PA
4DA(+28 BIT I/O),
DIA in E-PA
EA Type
Module type member
75x-532
DO_8
DO_DIA_8
DO_16
DO_DIA_16
DO_32
DO_DIA_32
75x-532*
DO_0
DO_DIA_0
Length
Bit allocation
[Bit]
7
6
5
2
2
2
4
\ - - - - - - - - - - - - - - Output - - - - - - - - - - - - - - /
4
\ - - - - - - - - - - - - - - Output - - - - - - - - - - - - - - /
4
\ - - - - - - - - - - - - - - Input - - - - - - - - - - - - - - /
Inputs
4
3
2
1
0
2
2
2
2
2
A3
A2
A1
A0
A3
A2
A1
A0
D3
D2
D1
D0
Instances
PNIOdata type
Input
-
Unsigned 8-Bit
field
1
-
Unsigned 16-Bit
field
1
-
Unsigned 32-Bit
field
1
-
-
Note
8, 16 or 32 bits are applied in the output
process image of the station proxy (fieldbus
coupler) by fitting a slot with these modules.
0
3
The bits 2
and 2
are assigned with the
signal condition of the physically connected
4
7
15
I/O module. The bits 2
to 2
, 2
or 2
marked green are made available for the
output and / or confirmation information of
the following modules. One byte process
data qualifier (IOCS) is managed in the
transmission direction of the I/O controller in
the cyclic PROFINET IO telegram for these
modules.
8, 16 or 32 bits are applied in the input and
output process image of the station proxy
(fieldbus coupler) by fitting a slot with these
0
3
modules. The bits 2
and 2
in the output
area are assigned with the signal condition of
the physically connected I/O module. The
2
7
15
31
bits 2
to 2
, 2
or 2
marked green are
made available for the output and / or
confirmation information of the following
0
3
modules. The bits 2
and 2
in the input area
are assigned with the diagnostics condition
of the physically connected I/O module. The
bits marked green are made available for the
input and / or diagnostics information of the
following module slots. Two byte process
data qualifiers (IOCS, IOPS) are managed in
the transmission direction of the I/O
controller in the cyclic PROFINET IO
telegram for these modules.
WAGO-I/O-SYSTEM 750
PROFINET IO
Output
1
1
1
1
1
1
-
31