24
Device Description
3.6.6
Control
Table 14: Technical data: Control
Mode
Connection type
Bus Control
Data transmission
Bus interface
Baud rate
Max. number of bus participants
Transmission medium
Central control via 24VDC signal
Operating voltage
Current consumption
Transmission medium
3.6.7
Setting and Operating Units
Table 15: Technical data: Setting and operating units
S5: DIP module 1
S6: DIP module 2
S7: IDC connector
Pos : 35 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
770-629/130-000 WINSTA® Sunblind Box 4 Channel
Bus control or
central control via 24VDC signal
Socket without strain relief housing,
4-pole
(Item No. 770-244)
Strain relief housing, 4-pole
(Item No. 770-514)
Serial, master-slave procedure
Serial Interface RS-485
9,600 baud
16
Screened bus cable:
YCYM 2 x 2 x 0.8 mm
max. 800 m
DC 24 V +10%/-50%
max. 5 mA
Screened bus line:
YCYM 2 x 2 x 0.8 mm
Setting of bus addresses
Setting of group formation, operating
time, operating logic/operating mode
Switching between bus version and
central version using a jumper
Version 1.2.0, valid from HW/FW version XXXX0201XX
WAGO WINSTA® 770
2
,
2
Manual