6.4 Speed Feedforward Function

6.4.2 Setting Parameters

6.4.2

Setting Parameters

Speed Feedforward Average Movement Time (Pn30C)
If the communications cycle with the host controller is slow, the speed feedforward reference
may be applied stepwise as shown on the left in the following figure.
v
Communications cycle
You can set Pn30C (Speed Feedforward Average Movement Time) to a suitable value to create
a smooth speed feedforward reference, as shown on the right in the above figure.
As a guideline, set Pn30C to the same value as the communications cycle.
Pn30C
6-10
Speed Feedforward Average Movement Time
Setting Range
Setting Unit
0 to 5,100
v
t
Position
Default Setting When Enabled
0
Immediately
t
Classification
Setup

Advertisement