2.4

Servo Command Format

This section describes the specifications of the servo commands.
The servo commands are specified by the 32-byte command and response data in the com-
munication specifications as shown in the table below.
The command/response data area can be expanded to 48 bytes by using subcommands. For
the subcommands, refer to the following chapter.
Chapter 4 Subcommands
The following table shows the format of the servo command and response data.
Byte
Command
0
1
2
CMD_CTRL
3
4
5
SVCMD_CTRL
6
7
8
9
SVCMD_IO
10
11
12
13
14
15
16
17
18
19
20
21
CMD_DATA
22
23
24
25
26
27
28
29
30
31
Response
CMD
RCMD
WDT
RWDT
CMD_STAT
SVCMD_STAT
SVCMD_IO
RSP_DATA
Description
• CMD_CTRL: Refer to the following section.
2.2.3 Command Control (CMD_CTRL) on page 2-6.
• CMD_STAT: Refer to the following section.
2.2.4 Command Status (CMD_STAT) on page 2-7.
• SVCMD_CTRL: Refer to the following section.
2.5.1 Servo Command Control (SVCMD_CTRL) on
page 2-14.
• SVCMD_STAT: Refer to the following section.
2.5.2 Servo Command Status (SVCMD_STAT) on page
2-16.
• SVCMD_IO: Refer to the following section.
2.6 Servo Command I/O Signal (SVCMD_IO) on page
2-22.
• CMD_DATA/RSP_DATA:
Specified for individual commands.

2.4 Servo Command Format