Clear Alarm Or Warning Subcommand (Alm_Clr: 06H) - YASKAWA S-7 Series Command Manual

Mechatrolink-iii ac servo drive communications standard servo profile
Hide thumbs Also See for S-7 Series:
Table of Contents

Advertisement

4.4

Clear Alarm or Warning Subcommand (ALM_CLR: 06h)

Data Format
Phases in which the
Command can be Executed
Processing Time
Byte
Command
32
33
34
SUB_CTRL
35
36
ALM_CLR_MOD
37
38
39
40
41
42
43
44
45
46
47
Command Parameters
The details of ALM_CLR_MOD are described below.
ALM_CLR_MOD
0
1
2, 3
Refer to the
specifications of
ALM_RD_MOD
ALM_CLR
Response
06h
06h
SUB_STAT
ALM_CLR_MOD
Reserved
Reserved
Description
Clearance of the current alarm or warning state
Clearance of the alarm history

4.4 Clear Alarm or Warning Subcommand (ALM_CLR: 06h)

Command
Classification
Common
command
Subcommand
Description
• The ALM_CLR subcommand clears the alarm or warning
state. It changes the state of a slave station, but does
not eliminate the cause of the alarm or warning. ALM_-
CLR should be used to clear the state after the cause of
the alarm or warning has been eliminated.
• Confirm the completion of the subcommand execution
by checking that RSUBCMD = ALM_CLR (= 06h) and
SUB_STAT.SBCMDRDY = 1.
In the following cases, an alarm will occur and the sub-
command will not be executed.
• When the ALM_CLR_MOD data is invalid:
SUBCMD_ALM = 9h (A.94B)
• While editing using SigmaWin or digital operator:
SUBCMD_ALM = Ah (A.95A)
Within 200 ms
Within 2 s
Asynchronous
command
Processing Time
4
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for: