Reading and Setting Parameters

The PLC can write drive parameters, read drive data and operation status, and change
settings.
Follow the directions below.
1.
Set the command code to remote register RW
Set the write data to RW
2.
Switch ON the RYF signal (request to execute the command code).
• Drive executes the process and reply data that correspond with the command
code.
• Command codes for drive parameters should be calculated by adding the
values shown below to the MEMOBUS/Modbus register number.
Read command code: MEMOBUS/Modbus register + 1000 (Hex.)
Write command code: MEMOBUS/Modbus register + 2000 (Hex.)
Example: Acceleration time command code for C1-01 [Acceleration Time 1] is
200 (Hex.). Get the read command code by adding 1000 (Hex.), yielding 1200
(Hex.).
Note:
1. For a list of command codes, write data drives, and setting ranges, refer to the instruction manual
for the drive the CC-Link Option is connected to.
2. Refer to the MEMOBUS/Modbus Data Table in Appendix C of the instruction manual for the drive
the CC-Link option is connected to for a list of monitor data using the MEMOBUS/Modbus
message area.
Access Method to Parameter of MEMOBUS Register Number 1000 (Hex.)
or Later
When setting and reading parameters of the MEMOBUS register number 1000 (Hex.) or
later from the PLC, set the MEMOBUS register number 1000 (Hex.) or later to the
register number 0C00 (Hex.) to 0C0F (Hex.) from the CC-Link communications. You can
access the value of the parameters 1000 (Hex.) or later specified by the MEMOBUS
register number 0C00 (Hex.) to 0C0F (Hex.) with the register number 0C80 (Hex.) to
0C8F (Hex.).
This function is available in the option versions PRG:0103 and later.
Table 7.1 List of MEMOBUS Register Numbers and Descriptions
Register No. (Hex.)
0C00
0C01
0C02
0C03
YASKAWA TOEP C730600 83A CC-Link Installation Manual
as needed.
W3
Register number setting 1
Register number setting 2
Register number setting 3
Register number setting 4