6.7 Acceleration/Deceleration Parameter High-speed Switching Function
• Setting Example 1: Switching three banks of members Pn80B, Pn80E, and Pn80C
Pn900 = 3
Pn901 = 3
Pn902 = 80Bh
Pn903 = 80Eh
Pn904 = 80Ch
• Setting Example 2: Switching two banks of members Pn836, Pn83C, and Pn838
Pn900 = 2
Pn901 = 6
Pn902 = 836h
Pn903 = 836h
Pn904 = 83Ch
Pn905= 83Ch
Pn906 = 838h
Pn907 = 838h
 Application Notes
• If Pn900 (Number of Parameter Banks) or Pn901 (Number of Parameter Bank Members) is
set to 0, the bank function will be disabled.
• If one parameter is registered for more than one bank member definition, the bank data of the
biggest bank member definition parameter number will be applied.
• The acceleration/deceleration parameter high-speed switching function is enabled only while
DEN = 1 (distribution completed). The parameters will not switch while DEN = 0 (distributing).
However, this does not apply to changing the S-curve acceleration/deceleration ratio
(Pn846).
• In the following cases, error A.04A (Parameter Setting Error 2) will occur when the power
supply is turned back ON or CONFIG command is executed.
• One 4-byte parameter is not registered for two consecutive bank members.
• The total number of bank data entries exceeds 64 (Pn900 × Pn901 > 64).
• If a parameter that is not allowed to be a bank member is registered, the bank data of the
parameter-registered member will become invalid.
• Bank data that exceeds the setting range of the registered bank member parameter will be
clamped to a value within the setting range.
• If a bank number larger than the bank number set in Pn900 is specified (BANK_SEL1 ≥
Pn900), the parameter bank will not switch and the currently active bank will be used.
• The parameters Pn920 to Pn95F will not be stored in the non-volatile memory. They need to
be set every time the power is turned ON.
6-20
Pn920 = 80Bh value
Bank number
Pn921 = 80Eh value
Member number
Pn922 = 80Ch value
Member 1
Pn923 = 80Bh value
Member 2
Pn924 = 80Eh value
Member 3
Pn925 = 80Ch value
Pn926 = 80Bh value
Pn927 = 80Eh value
Pn928 = 80Ch value
Bank number
Pn920 = 836h LS word
Pn921 = 836h MS word
Member number
Pn922 = 83Ch LS word
Member 1
Pn923 = 83Ch MS word
Member 2
Pn924 = 838h LS word
Member 3
Pn925 = 838h MS word
Member 4
Pn926 = 836h LS word
Member 5
Pn927 = 836h MS word
Member 6
Pn928 = 83Ch LS word
Pn929 = 83Ch MS word
Pn92A = 838h LS word
Pn92B = 838h MS word
Bank 0
Bank 1
Bank 2
Bank 0
Bank 1