Parameter Descriptions
0-40 [Hand on] Key on LCP
Option:
Function:
[0] Disabled
No effect when [Hand On] is pressed. Select
[0] Disabled to avoid accidental start of the
frequency converter in Hand on mode.
[1] Enabled
The LCP switches to Hand on mode directly
when [Hand on] is pressed.
[2] Password
After pressing [Hand on] a password is
required. If parameter 0-40 [Hand on] Key on
LCP is included in My Personal Menu, define
the password in parameter 0-65 Quick Menu
Password. Otherwise define the password in
parameter 0-60 Main Menu Password.
[3] Hand Off/On When [Hand On] is pressed once, the LCP
switches to Off mode. When pressed again, the
LCP switches to Hand on mode.
[4] Hand Off/On
Same as [3] but a password is required (see
w. Passw.
option [2] Password).
[9] Enabled, ref
= 0
0-41 [Off] Key on LCP
Option:
Function:
[0] Disabled
Avoids accidental stop of the frequency converter.
[1] Enabled
[2] Password Avoids unauthorized stop. If parameter 0-41 [Off]
Key on LCP is included in the Quick Menu, then
define the password in parameter 0-65 Quick Menu
Password.
0-42 [Auto on] Key on LCP
Option:
Function:
[0] Disabled
Avoids accidental start of the frequency converter
in Auto On mode.
[1] Enabled
[2] Password Avoids unauthorized start in Auto On mode. If
parameter 0-42 [Auto on] Key on LCP is included in
the Quick Menu, then define the password in
parameter 0-65 Quick Menu Password.
0-43 [Reset] Key on LCP
Option:
Function:
[0] Disabled
No effect when [Reset] is pressed. Avoids
accidental alarm reset.
[1] Enabled
[2] Password
Avoids unauthorized resetting. If
parameter 0-43 [Reset] Key on LCP is included in
the Quick Menu, then define the password in
parameter 0-65 Quick Menu Password.
[7] Enabled
Resets the frequency converter without setting
without OFF
it in Off mode.
MG33ML02
Programming Guide
0-43 [Reset] Key on LCP
Option:
[8] Password
without OFF
0-44 [Off/Reset] Key on LCP
Enable or disable the [Off/Reset] key.
Option:
[0]
[1]
[2]
0-45 [Drive Bypass] Key on LCP
Press [Off] and select [0] Disabled to avoid unintended stop of
the frequency converter. Press [Off] and select [2] Password to
avoid unauthorized bypass of the frequency converter. If
parameter 0-45 [Drive Bypass] Key on LCP is included in the Quick
Menu, define the password in parameter 0-65 Personal Menu
Password.
Option:
[0]
[1]
[2]
3.2.6 0-5* Copy/Save
Copy parameters from and to the LCP. Use these
parameters for saving and copying set-ups from 1
frequency converter to another.
0-50 LCP Copy
Option:
[0]
No copy
*
[1]
All to LCP
[2]
All from LCP
[3]
Size indep. from
LCP
Danfoss A/S © 02/2016 All rights reserved.
Function:
Resets the frequency converter without setting
it in Off mode. A password is required when
pressing [Reset] (see option [2] Password).
Function:
Disabled
Enabled
Password
Function:
Disabled
Select to disable the
key.
Enabled
Password
Function:
NOTICE
This parameter cannot be
adjusted while the motor is
running.
Copies all parameters in all set-ups
from the frequency converter memory
to the LCP memory.
Copies all parameters in all set-ups
from the LCP memory to the frequency
converter memory.
Copy only the parameters that are
independent of the motor size. The
latter selection can be used to program
several frequency converters with the
same function without disturbing
motor data.
3
3
37