Parameter Descriptions
0-20 Display Line 1.1 Small
Option:
[1667]
Freq. Input #29 [Hz] Actual value of the frequency
3
3
[1668]
Freq. Input #33 [Hz] Actual value of the frequency
[1669]
Pulse Output #27
[Hz]
[1670]
Pulse Output #29
[Hz]
[1671]
Relay Output [bin]
[1672]
Counter A
[1673]
Counter B
[1674]
Prec. Stop Counter
[1675]
Analog In X30/11
[1676]
Analog In X30/12
[1677]
Analog Out X30/8
[mA]
[1678]
Analog Out X45/1
[mA]
[1679]
Analog Out X45/3
[mA]
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[1684]
Comm. Option STW Extended fieldbus communication
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
[1687]
Bus Readout
Alarm/Warning
[1689]
Configurable
Alarm/Warning
Word
[1690]
Alarm Word
[1691]
Alarm Word 2
[1692]
Warning Word
34
®
VLT
AutomationDrive FC 301/302
Function:
applied at terminal 29 as an
impulse input.
applied at terminal 33 as an
impulse input.
Actual value of impulses applied to
terminal 27 in digital output mode.
Actual value of impulses applied to
terminal 29 in digital output mode.
Application dependent (for
example SLC control).
Application dependent (for
example SLC control).
Shows the actual value of the
counter.
Actual value at input X30/11 either
as reference or protection value.
Actual value at input X30/12 either
as reference or protection value.
Actual value at output X30/8 in
mA. Use parameter 6-60 Terminal
X30/8 Output to select the value to
be shown.
Control word (CTW) received from
the bus master.
Main reference value sent with
control word from the bus master.
option status word.
Control word (CTW) received from
the bus master.
Status word (STW) sent to the bus
master.
1 or more alarms in a hex code.
1 or more alarms in a hex code.
1 or more warnings in a hex code.
Danfoss A/S © 02/2016 All rights reserved.
0-20 Display Line 1.1 Small
Option:
Function:
[1693]
Warning Word 2
1 or more warnings in a hex code.
[1694]
Ext. Status Word
1 or more status conditions in a
hex code.
[1836]
Analog Input X48/2
[mA]
[1837]
Temp. Input X48/4
[1838]
Temp. Input X48/7
[1839]
Temp. Input X48/10
[1860]
Digital Input 2
[3110]
Bypass Status Word
[3111]
Bypass Running
Hours
[4235]
S-CRC Value
[4282]
Safe Control Word
[4283]
Safe Status Word
[4285]
Active Safe Func.
[4286]
Safe Option Info
[9913]
Idle time
[9914]
Paramdb requests
in queue
[9917]
tCon1 time
[9918]
tCon2 time
[9919]
Time Optimize
Measure
[9920]
HS Temp. (PC1)
[9921]
HS Temp. (PC2)
[9922]
HS Temp. (PC3)
[9923]
HS Temp. (PC4)
[9924]
HS Temp. (PC5)
[9925]
HS Temp. (PC6)
[9926]
HS Temp. (PC7)
[9927]
HS Temp. (PC8)
[9951]
PC Debug 0
[9952]
PC Debug 1
[9953]
PC Debug 2
[9954]
PC Debug 3
[9955]
PC Debug 4
[9956]
Fan 1 Feedback
[9957]
Fan 2 Feedback
[9958]
PC Auxiliary Temp
[9959]
Power Card Temp.
0-21 Display Line 1.2 Small
Select a variable for display in line 1, middle position. The
options are the same as those listed for parameter 0-20 Display
Line 1.1 Small.
0-22 Display Line 1.3 Small
Select a variable for display in line 1, right position. The options
are the same as those listed for parameter 0-20 Display Line 1.1
Small.