Danfoss VLT AutomationDrive FC 301 Programming Manual page 213

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
4.1.8 4-** Limits/Warnings
Par-
Parameter description
ameter #
4-1* Motor Limits
4-10
Motor Speed Direction
4-11
Motor Speed Low Limit [RPM]
4-12
Motor Speed Low Limit [Hz]
4-13
Motor Speed High Limit [RPM]
4-14
Motor Speed High Limit [Hz]
4-16
Torque Limit Motor Mode
4-17
Torque Limit Generator Mode
4-18
Current Limit
4-19
Max Output Frequency
4-2* Limit Factors
4-20
Torque Limit Factor Source
4-21
Speed Limit Factor Source
4-23
Brake Check Limit Factor Source
4-24
Brake Check Limit Factor
4-3* Motor Speed Mon.
4-30
Motor Feedback Loss Function
4-31
Motor Feedback Speed Error
4-32
Motor Feedback Loss Timeout
4-34
Tracking Error Function
4-35
Tracking Error
4-36
Tracking Error Timeout
4-37
Tracking Error Ramping
4-38
Tracking Error Ramping Timeout
Tracking Error After Ramping
4-39
Timeout
4-4* Speed Monitor
4-43
Motor Speed Monitor Function
4-44
Motor Speed Monitor Max
4-45
Motor Speed Monitor Timeout
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-52
Warning Speed Low
4-53
Warning Speed High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
4-61
Bypass Speed From [Hz]
4-62
Bypass Speed To [RPM]
4-63
Bypass Speed To [Hz]
4-7* Position Monitor
MG33ML02
Programming Guide
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
[0] DC-link voltage
All set-ups
98 %
All set-ups
[2] Trip
All set-ups
300 RPM
All set-ups
0.05 s
All set-ups
ExpressionLimit
All set-ups
10 RPM
All set-ups
1 s
All set-ups
100 RPM
All set-ups
1 s
All set-ups
5 s
All set-ups
[0] Disabled
All set-ups
100 RPM
All set-ups
0.1 s
All set-ups
0 A
All set-ups
ImaxVLT (P1637)
All set-ups
0 RPM
All set-ups
ExpressionLimit
All set-ups
-999999.999 N/A
All set-ups
999999.999 N/A
All set-ups
-999999.999
ReferenceFeed-
backUnit
All set-ups
999999.999
ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
Danfoss A/S © 02/2016 All rights reserved.
Change during
Conversion
operation
index
FALSE
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-1
TRUE
-1
FALSE
-1
TRUE
TRUE
TRUE
TRUE
0
TRUE
TRUE
67
TRUE
-2
TRUE
TRUE
67
TRUE
-2
TRUE
67
TRUE
-2
TRUE
-2
TRUE
TRUE
67
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
67
TRUE
67
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
Type
Uint8
Uint16
Uint16
4
4
Uint16
Uint16
Uint16
Uint16
Uint32
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint16
Uint16
Uint16
211