Danfoss VLT AutomationDrive FC 301 Programming Manual page 22

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

How to Program
Operating variable
Parameter 16-32 Brake Energy /s
2
2
Parameter 16-33 Brake Energy Average
Parameter 16-34 Heatsink Temp.
Parameter 16-35 Inverter Thermal
Parameter 16-36 Inv. Nom. Current
Parameter 16-37 Inv. Max. Current
Parameter 16-38 SL Controller State
Parameter 16-39 Control Card Temp.
Parameter 16-40 Logging Buffer Full
Parameter 16-50 External Reference
Parameter 16-51 Pulse Reference
Parameter 16-52 Feedback[Unit]
Parameter 16-53 Digi Pot Reference
Parameter 16-60 Digital Input
Parameter 16-61 Terminal 53 Switch Setting
Parameter 16-62 Analog Input 53
Parameter 16-63 Terminal 54 Switch Setting
Parameter 16-64 Analog Input 54
Parameter 16-65 Analog Output 42 [mA]
Parameter 16-66 Digital Output [bin]
Parameter 16-67 Pulse Input #29 [Hz]
Parameter 16-68 Freq. Input #33 [Hz]
Parameter 16-69 Pulse Output #27 [Hz]
Parameter 16-70 Pulse Output #29 [Hz]
Parameter 16-71 Relay Output [bin]
Parameter 16-72 Counter A
Parameter 16-73 Counter B
Parameter 16-80 Fieldbus CTW 1
Parameter 16-82 Fieldbus REF 1
Parameter 16-84 Comm. Option STW
Parameter 16-85 FC Port CTW 1
Parameter 16-86 FC Port REF 1
Parameter 16-90 Alarm Word
Parameter 16-92 Warning Word
Parameter 16-94 Ext. Status Word
Table 2.1 Units
20
®
VLT
AutomationDrive FC 301/302
Status view I
Unit
This readout state is standard after start-up or initialization.
kW
Press [Info] to obtain information about the units linked to
kW
the shown operating variables (1.1, 1.2, 1.3, 2 and 3).
ºC
See the operating variables shown in Illustration 2.10.
%
A
A
°C
[Unit]
bin
Illustration 2.10 Status View I
V
V
Status view II
See the operating variables (1.1, 1.2, 1.3, and 2) shown in
[mA]
Illustration 2.11.
[bin]
In the example, speed, motor current, motor power, and
[Hz]
frequency are selected as variables in the first and second
[Hz]
lines.
[Hz]
[Hz]
hex
hex
hex
hex
hex
Illustration 2.11 Status View II
Status view III
This state shows the event and action of the smart logic
control. For further information, see
chapter 3.14 Parameters: 13-** Smart Logic Control.
Illustration 2.12 Status View III
Danfoss A/S © 02/2016 All rights reserved.
Status
799 RPM
7.83 A
1.1
0.000
1.2
53.2 %
Auto Remote Ramping
2
3
1.3
Status
207RPM
5.25A
1.1
6.9
Hz
Auto Remote Running
Status
778 RPM
0.86 A
State: 0 o 0 (o )
When: -
Do: -
Auto Remote Running
1 (1)
36.4 kw
1 (1)
24.4 kW
1.3
1.2
2
1 (1)
4.0 kW
MG33ML02