Danfoss VLT AutomationDrive FC 301 Programming Manual page 218

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
8-19
Product Code
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-33
Parity / Stop Bits
8-34
Estimated cycle time
4
4
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram Selection
8-41
Parameters for Signals
8-42
PCD Write Configuration
8-43
PCD Read Configuration
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Profidrive OFF2 Select
8-58
Profidrive OFF3 Select
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Messages Rcvd
8-83
Slave Error Count
8-9* Bus Jog
8-90
Bus Jog 1 Speed
8-91
Bus Jog 2 Speed
4.1.13 9-** Profibus
Par-
Parameter description
ameter #
9-00
Setpoint
9-07
Actual Value
9-15
PCD Write Configuration
9-16
PCD Read Configuration
9-18
Node Address
9-19
Drive Unit System Number
9-22
Telegram Selection
9-23
Parameters for Signals
9-27
Parameter Edit
9-28
Process Control
9-44
Fault Message Counter
9-45
Fault Code
9-47
Fault Number
216
®
VLT
AutomationDrive FC 301/302
ExpressionLimit
1 set-up
[0] FC
1 set-up
1 N/A
1 set-up
ExpressionLimit
1 set-up
[0] Even Parity, 1
Stop Bit
1 set-up
0 ms
2 set-ups
10 ms
1 set-up
ExpressionLimit
1 set-up
ExpressionLimit
1 set-up
[1] Standard
telegram 1
2 set-ups
0
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
ExpressionLimit
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
100 RPM
All set-ups
ExpressionLimit
All set-ups
Default value
4 set-up
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
1 set-up
ExpressionLimit
2 set-ups
126 N/A
1 set-up
1034 N/A
All set-ups
[100] None
1 set-up
0
All set-ups
[1] Enabled
2 set-ups
[1] Enable cyclic
master
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Danfoss A/S © 02/2016 All rights reserved.
TRUE
0
TRUE
TRUE
0
TRUE
TRUE
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-5
TRUE
FALSE
TRUE
0
TRUE
0
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
67
TRUE
67
Change during
Conversion
operation
index
TRUE
0
FALSE
0
TRUE
TRUE
TRUE
0
TRUE
0
TRUE
TRUE
FALSE
FALSE
TRUE
0
TRUE
0
TRUE
0
Uint32
Uint8
Uint8
Uint8
Uint8
Uint32
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Type
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint8
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
MG33ML02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents