Parameter Descriptions
0-13 Readout: Linked Set-ups
Array [5]
Range:
0
[0 -
*
255 ]
3
3
0-14 Readout: Edit Set-ups / Channel
Range:
0
[-2147483648 -
*
2147483647]
0-15 Readout: actual setup
Range:
0
[0 - 255] Makes it possible to read out the active set-up,
*
32
Function:
View a list of all the set-ups linked by
parameter 0-12 This Set-up Linked to. The parameter
has 1 index for each parameter set-up. The value
for each index shows which set-ups are linked to
that parameter set-up.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 3.1 Set-up Link Example
Function:
View the setting of parameter 0-11 Edit Set-
up for each of the 4 different
communication channels. When the
number is displayed as a hex number, as it
is in the LCP, each number represents 1
channel.
Numbers 1–4 represent a set-up number; F
means factory setting; and A means active
set-up. The channels are, from right to left:
LCP, FC bus, USB, HPFB1-5.
Example: The number AAAAAA21h means
the following:
The frequency converter received
the setting set-up 2 via a fieldbus
channel. This selection is reflected
in parameter 0-11 Edit Set-up.
A user selected set-up 1 via the
LCP.
All other channels are using the
active set-up.
Function:
also when [9] Multi set-up is selected in
parameter 0-10 Active Set-up.
Danfoss A/S © 02/2016 All rights reserved.
®
VLT
AutomationDrive FC 301/302
3.2.3 0-2* LCP Display
Define the variables shown in the LCP.
NOTICE
For information on how to write display texts, refer to:
0-20 Display Line 1.1 Small
Option:
[0]
[9]
[15]
[37]
[38]
[39]
[953]
[1005]
[1006]
[1007]
[1013]
[1230]
[1472]
[1473]
[1474]
[1501]
[1502]
[1580]
[1600]
[1601]
[1602]
[1603]
Parameter 0-37 Display Text 1.
Parameter 0-38 Display Text 2.
Parameter 0-39 Display Text 3.
Function:
Select a variable for display in line
1, left position.
None
No display value selected.
Performance
Monitor
Readout: actual
setup
Display Text 1
Display Text 2
Display Text 3
Profibus Warning
Word
Readout Transmit
Error Counter
Readout Receive
Error Counter
Readout Bus Off
Counter
Warning Parameter
Warning Parameter
Legacy Alarm Word
Legacy Warning
Word
Leg. Ext. Status
Word
Running Hours
kWh Counter
Fan Running Hours
Control Word
Present control word.
Reference [Unit]
Total reference (sum of digital/
analog/preset/bus/freeze reference/
catch up and slow down) in
selected unit.
Reference %
Total reference (sum of digital/
analog/preset/bus/freeze reference./
catch up and slow down) in
percent.
Status Word
Present status word.
MG33ML02