11 Complete the configuration

11.1 Test or tune the system using sensor simulation

Display
Menu > Service Tools > Sensor Simulation > Simulate Sensor
ProLink III
Device Tools > Diagnostics > Testing > Sensor Simulation
Web browser
Service Tools > Simulation > Sensor Simulation
Use sensor simulation to test the system's response to a variety of process conditions, including boundary
conditions, problem conditions, or alert conditions, or to tune the loop.
Prerequisites
Before enabling sensor simulation, ensure that your process can tolerate the effects of the simulated process
values.
Procedure
1. Enable sensor simulation.
2. For mass flow, set Wave Form as desired and enter the required values.
Option
Fixed
Sawtooth
Sine
3. For density, set Wave Form as desired and enter the required values.
Option
Fixed
Sawtooth
Sine
4. For temperature, set Wave Form as desired and enter the required values.
Configuration and Use Manual
Required values
Fixed Value
Period
Minimum
Maximum
Period
Minimum
Maximum
Required values
Fixed Value
Period
Minimum
Maximum
Period
Minimum
Maximum