7

Complete the configuration

Topics covered in this chapter:
7.1
Test or tune the system using sensor
simulation
Use sensor simulation to test the system's response to a variety of process conditions,
including boundary conditions, problem conditions, or alert conditions, or to tune the
loop.
Restriction
Sensor simulation is available only on flowmeters with the enhanced core processor.
Prerequisites
Before enabling sensor simulation, ensure that your process can tolerate the effects of the
simulated process values.
Procedure
1.
2.
3.
Configuration and Use Manual

Test or tune the system using sensor simulation

Back up transmitter configuration
Enable write-protection on the transmitter configuration
Navigate to the sensor simulation menu.
Communications tool
Display
ProLink III
Field Communicator
Enable sensor simulation.
For mass flow, set Wave Form as desired and enter the required values.
Option
Fixed
Sawtooth
Menu path
Not available
Device Tools > Diagnostics > Testing > Sensor Simulation
Service Tools > Simulate > Simulate Sensor
Required values
Fixed Value
Period
Minimum
Maximum
Complete the configuration