Configure process measurement
March 2019
If the gas standard volume flow rate drops below 10 SLPM, both outputs will report zero flow, and 0 will be
used in all internal processing.

4.5 Configure density measurement

The density measurement parameters control how density is measured and reported. Density measurement
is used with mass flow rate measurement to determine liquid volume flow rate.
4.5.1 Configure Density Measurement Unit
Display
Menu > Configuration > Process Measurement > Density > Units
ProLink III
Device Tools > Configuration > Process Measurement > Density > Density Unit
Configuration > Process Measurement > Density > Density Unit
Web browser
Density Measurement Unit controls the measurement units that will be used in density calculations and
reporting.
Restriction
If the API referral application is enabled, you cannot change the density measurement unit here. The density
measurement unit is controlled by the API table selection.
Procedure
Set Density Measurement Unit to the option you want to use.
Default: g/cm³ (grams per cubic centimeter)
Options for Density Measurement Unit
The transmitter provides a standard set of measurement units for Density Measurement Unit. Different
communications tools may use different labels.
Unit description
(1)
Specific gravity
Grams per cubic centimeter
Grams per liter
Grams per milliliter
Kilograms per liter
Kilograms per cubic meter
Pounds per U.S. gallon
Pounds per cubic foot
Pounds per cubic inch
Degrees API
44
Display
SGU
g/cm3
g/L
g/mL
kg/L
kg/m3
lb/gal
lb/ft3
lb/in3
API
Configuration and Use Manual
Label
ProLink III
SGU
g/cm3
g/l
g/ml
kg/l
kg/m3
lbs/USgal
lbs/ft3
lbs/in3
API
Micro Motion Model 5700 with Ethernet Transmitters
MMI-20029769
Web browser
SGU
g/cm3
g/l
g/ml
kg/l
kg/m3
lb/USgal
lb/ft3
lb/in3
°API