Data Read-Outs - Danfoss VLT AutomationDrive FC 360 Programming Manual

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Parameter Lists
15-51
Drive Serial Number
15-53
Power Card Serial Number
15-6* Option Ident
15-60
Option Mounted
15-61
Option SW Version
15-62
Option Ordering No
15-63
Option Serial No
15-70
Option in Slot A
15-71
Slot A Option SW Version
15-9* Parameter Info
15-92
Defined Parameters
5
5
15-97
Application Type
15-98
Drive Identification
15-99
Parameter Metadata

5.1.18 16-** Data Read-outs

Par. No. #
Parameter description
16-0* General Status
16-00
Control Word
16-01
Reference [Unit]
16-02
Reference [%]
16-03
Status Word
16-05
Main Actual Value [%]
16-09
Custom Readout
16-1* Motor Status
16-10
Power [kW]
16-11
Power [hp]
16-12
Motor Voltage
16-13
Frequency
16-14
Motor current
16-15
Frequency [%]
16-16
Torque [Nm]
16-18
Motor Thermal
16-22
Torque [%]
16-3* Drive Status
16-30
DC Link Voltage
16-33
Brake Energy /2 min
16-34
Heatsink Temp.
16-35
Inverter Thermal
16-36
Inv. Nom. Current
16-37
Inv. Max. Current
16-38
SL Controller State
16-39
Control Card Temp.
16-5* Ref. & Feedb.
16-50
External Reference
16-52
Feedback[Unit]
16-53
Digi Pot Reference
16-57
Feedback [RPM]
16-6* Inputs & Outputs
16-60
Digital Input
126
Programming Guide
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Default value
0 N/A
0 ReferenceFeedbackUnit
0 %
0 N/A
0 %
0 CustomReadoutUnit
0 kW
0 hp
0 V
0 Hz
0 A
0 %
0 Nm
0 %
0 %
0 V
0 kW
0 °C
0 %
0 A
0 A
0 N/A
0 °C
0 %
0 ProcessCtrlUnit
0 N/A
0 RPM
0 N/A
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
FALSE
1 set-up
FALSE
2-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
0
VisStr[13]
0
VisStr[21]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[18]
0
VisStr[30]
0
VisStr[20]
0
Uint16
0
Uint32
0
VisStr[56]
0
Uint16
Type
0
Uint16
-3
Int32
-1
Int16
0
Uint16
-2
Int16
-2
Int32
-3
Uint32
-3
Uint32
-1
Uint32
-1
Uint32
-2
Uint16
-1
Uint16
-1
Int32
0
Uint8
0
Int16
0
Uint32
0
Uint32
100
Int8
0
Uint8
-2
Uint16
-2
Uint16
0
Uint8
100
Uint16
-1
Int16
-3
Int32
-2
Int16
67
Int32
0
Uint16
MG06C402