Parameter Lists
1-16
High Speed Filter Time Const.
1-17
Voltage filter time const.
1-2* Motor Data
1-20
Motor Power
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-29
Automatic Motor Adaption (AMA)
1-3* Adv. Motor Data I
5
5
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-33
Stator Leakage Reactance (X1)
1-35
Main Reactance (Xh)
1-37
d-axis Inductance (Ld)
1-38
q-axis Inductance (Lq)
1-39
Motor Poles
1-4* Adv. Motor Data II
1-40
Back EMF at 1000 RPM
1-42
Motor Cable Length
1-43
Motor Cable Length Feet
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-52
Min Speed Normal Magnetising [Hz]
1-55
U/f Characteristic - U
1-56
U/f Characteristic - F
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
1-7* Start Adjustments
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-75
Start Speed [Hz]
1-76
Start Current
1-78
Compressor Start Max Speed [Hz]
1-79
Compressor Start Max Time to Trip
1-8* Stop Adjustments
1-80
Function at Stop
1-82
Min Speed for Function at Stop [Hz]
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-93
Thermistor Source
116
Programming Guide
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
50 m
164 ft
100 %
1 Hz
ExpressionLimit
ExpressionLimit
100 %
100 %
ExpressionLimit
0.1 s
100 %
0.005 s
50 %
0 s
[2] Coast/delay time
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 Hz
5 s
[0] Coast
0 Hz
[0] No protection
[0] None
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
All set-ups
TRUE
-2
All set-ups
TRUE
-3
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
-2
All set-ups
FALSE
67
All set-ups
FALSE
-1
All set-ups
FALSE
All set-ups
FALSE
-3
All set-ups
FALSE
-3
All set-ups
FALSE
-3
All set-ups
FALSE
-2
All set-ups
FALSE
-3
All set-ups
FALSE
-6
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
-1
All set-ups
FALSE
-1
All set-ups
FALSE
-1
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-2
All set-ups
TRUE
All set-ups
TRUE
-3
All set-ups
TRUE
All set-ups
TRUE
-1
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-1
All set-ups
TRUE
-2
All set-ups
TRUE
-1
All set-ups
TRUE
-1
All set-ups
TRUE
All set-ups
TRUE
-1
All set-ups
TRUE
All set-ups
FALSE
Uint16
Uint16
-
Uint8
0
Uint16
0
Uint16
Uint32
Uint16
Uint32
-
Uint8
Uint32
Uint32
Uint32
Uint32
Int32
Int32
0
Uint8
0
Uint16
0
Uint8
0
Uint16
0
Uint16
Uint16
Uint16
Uint16
0
Int16
0
Int16
0
Int16
Uint16
0
Uint16
Uint16
0
Uint32
Uint8
-
Uint8
-
Uint8
Uint16
Uint32
Uint16
Uint8
-
Uint8
Uint16
-
Uint8
-
Uint8
MG06C402