Digital Outputs - Danfoss VLT AutomationDrive FC 360 Programming Manual

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Parameter Descriptions
Available only if 1-00 Configuration Mode is set
to [6] Surface Winder or [7] Extended PID Speed
OL.
[74] PID enable When enabled, enables the extended process
PID controller. Equivalent to
parameter 7-50 Process PID Extended PID.
Available only if 1-00 Configuration Mode is set
to [7] Extended PID Speed OL.
Besides the selections above, default value and some extra
selections for specific terminals as below.
5-10 Terminal 18 Digital Input
Option:
Function:
[8]
Start Functions are described in parameter group 5-1*
*
Digital Inputs.
5-11 Terminal 19 Digital Input
Option:
Function:
[10]
Reversing Functions are described in parameter group
*
5-1* Digital Inputs.
5-12 Terminal 27 Digital Input
Option:
Function:
[2]
Coast inverse Functions are described in parameter group
*
5-1* Digital Inputs.
5-13 Terminal 29 Digital Input
Option:
Function:
[14]
Jog
Functions are described in parameter
*
group 5-1* Digital Inputs.
[32]
Pulse time based
5-14 Terminal 32 Digital Input
Option:
Function:
[0]
No operation
Functions are described in parameter
*
group 5-1* Digital Inputs.
[82] Encoder input B
5-15 Terminal 33 Digital Input
Option:
Function:
[0]
No operation
Functions are described in parameter
*
group 5-1* Digital Inputs.
[32] Pulse time based
[81] Enocder input A
5-16 Terminal 31 Digital Input
Option:
Function:
[0] No operation Functions are described in parameter group
5-1* Digital Inputs.

4.6.3 5-3* Digital Outputs

The 2 solid-state digital outputs are common for terminals
27 and 29. Set the I/O function for terminal 27 in
5-01 Terminal 27 Mode, and set the I/O function for
terminal 29 in 5-02 Terminal 29 Mode.
MG06C402
Programming Guide
Terminals 42 and 45 can also be configured as digital
outputs.
NOTICE
These parameters cannot be adjusted while the motor is
running.
5-30 to 5-31 Digital Outputs
[0]
No operation
[1]
Control ready
[2]
Drive ready
[3]
Drive ready /
remote control
[4]
Enable / no
warning
[5]
Running
[6]
Running / no
warning
[7]
Run in range /
no warning
[8]
Run on
reference / no
warning
[9]
Alarm
[10]
Alarm or
warning
[11]
At torque limit The torque limit set in 4-16 Torque Limit
[12]
Out of current
range
[13]
Below current,
low
[14]
Above current,
high
[15]
Out of
frequency
range
[16]
Below
frequency, low
[17]
Above
frequency,
high
[18]
Out of
feedback
range
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
Default for all digital outputs and relay
outputs.
The control card is ready.
The frequency converter is ready for
operation and applies a supply signal on
the control board.
The frequency converter is ready for
operation and is in [Auto On] mode.
Ready for operation. No start or stop
command is been given (start/disable). No
warnings are active.
Motor is running and shaft torque present.
Output speed is higher than the speed set
in 1-81 Min Speed for Function at Stop
[RPM]. The motor is running and there are
no warnings.
Motor is running within the programmed
current and speed ranges set in
4-50 Warning Current Low to 4-51 Warning
Current High. There are no warnings.
Motor runs at reference speed. No
warnings.
An alarm activates the output. There are
no warnings.
An alarm or a warning activates the
output.
Motor Mode or 4-17 Torque Limit Generator
Mode has been exceeded.
The motor current is outside the range set
in 4-18 Current Limit.
Motor current is lower than set in
4-50 Warning Current Low.
Motor current is higher than set in
4-51 Warning Current High.
Output frequency is outside the frequency
range.
Output speed is lower than the setting in
parameter 4-40 Warning Freq. Low.
Output speed is higher than the setting in
parameter 4-41 Warning Freq. High.
Feedback is outside the range set in
4-56 Warning Feedback Low and
4-57 Warning Feedback High.
4
4
51

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 360 and is the answer not in the manual?

Questions and answers

Table of Contents