Motion Control Adv. Settings; Motion Control Data Readouts - Danfoss VLT AutomationDrive FC 360 Programming Manual

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Parameter Lists

5.1.24 33-** Motion Control Adv. Settings

Par. No. #
Parameter description
33-00
Force Home
33-01
Home Offset
33-02
Home Ramp Time
33-03
Homing Velocity
33-04
Homing Type
33-41
Negative Software Limit
33-42
Positive Software Limit
33-43
Negative Software Limit Active
33-44
Positive Software Limit Active
33-47
Target Position Window

5.1.25 34-** Motion Control Data Readouts

Par. No. #
Parameter description
34-0* PCD Write Par.
34-01
PCD 1 Write For Application
34-02
PCD 2 Write For Application
34-03
PCD 3 Write For Application
34-04
PCD 4 Write For Application
34-05
PCD 5 Write For Application
34-06
PCD 6 Write For Application
34-07
PCD 7 Write For Application
34-08
PCD 8 Write For Application
34-09
PCD 9 Write For Application
34-10
PCD 10 Write For Application
34-2* PCD Read Par.
34-21
PCD 1 Read For Application
34-22
PCD 2 Read For Application
34-23
PCD 3 Read For Application
34-24
PCD 4 Read For Application
34-25
PCD 5 Read For Application
34-26
PCD 6 Read For Application
34-27
PCD 7 Read For Application
34-28
PCD 8 Read For Application
34-29
PCD 9 Read For Application
34-30
PCD 10 Read For Application
34-5* Process Data
34-50
Actual Position
34-56
Track Error
MG06C402
Programming Guide
Default value
[0] Home not forced
0 N/A
10 ms
100 RPM
[1] Reverse no index
-500000 N/A
500000 N/A
[0] Inactive
[0] Inactive
0 N/A
Default value
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
2-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
1 set-up
TRUE
0
1 set-up
TRUE
-3
1 set-up
TRUE
67
1 set-up
TRUE
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
0
2-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
Type
-
Uint8
Int32
Uint16
Int16
-
Uint8
Int32
5
5
Int32
-
Uint8
-
Uint8
Uint16
Type
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Int32
Int32