Parameter Lists
5.1.24 33-** Motion Control Adv. Settings
Par. No. #
Parameter description
33-00
Force Home
33-01
Home Offset
33-02
Home Ramp Time
33-03
Homing Velocity
33-04
Homing Type
33-41
Negative Software Limit
33-42
Positive Software Limit
33-43
Negative Software Limit Active
33-44
Positive Software Limit Active
33-47
Target Position Window
5.1.25 34-** Motion Control Data Readouts
Par. No. #
Parameter description
34-0* PCD Write Par.
34-01
PCD 1 Write For Application
34-02
PCD 2 Write For Application
34-03
PCD 3 Write For Application
34-04
PCD 4 Write For Application
34-05
PCD 5 Write For Application
34-06
PCD 6 Write For Application
34-07
PCD 7 Write For Application
34-08
PCD 8 Write For Application
34-09
PCD 9 Write For Application
34-10
PCD 10 Write For Application
34-2* PCD Read Par.
34-21
PCD 1 Read For Application
34-22
PCD 2 Read For Application
34-23
PCD 3 Read For Application
34-24
PCD 4 Read For Application
34-25
PCD 5 Read For Application
34-26
PCD 6 Read For Application
34-27
PCD 7 Read For Application
34-28
PCD 8 Read For Application
34-29
PCD 9 Read For Application
34-30
PCD 10 Read For Application
34-5* Process Data
34-50
Actual Position
34-56
Track Error
MG06C402
Programming Guide
Default value
[0] Home not forced
0 N/A
10 ms
100 RPM
[1] Reverse no index
-500000 N/A
500000 N/A
[0] Inactive
[0] Inactive
0 N/A
Default value
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
2-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
1 set-up
TRUE
0
1 set-up
TRUE
-3
1 set-up
TRUE
67
1 set-up
TRUE
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
0
2-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
Type
-
Uint8
Int32
Uint16
Int16
-
Uint8
Int32
5
5
Int32
-
Uint8
-
Uint8
Uint16
Type
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Int32
Int32
129
Need help?
Do you have a question about the VLT AutomationDrive FC 360 and is the answer not in the manual?
Questions and answers