Parameter Lists
9-63
Actual Baud Rate
9-64
Device Identification
9-65
Profile Number
9-67
Control Word 1
9-68
Status Word 1
9-70
Programming Set-up
9-71
Profibus Save Data Values
9-72
ProfibusDriveReset
9-75
DO Identification
9-80
Defined Parameters (1)
9-81
Defined Parameters (2)
9-82
Defined Parameters (3)
9-83
Defined Parameters (4)
9-84
Defined Parameters (5)
9-90
Changed Parameters (1)
9-91
Changed Parameters (2)
9-92
Changed Parameters (3)
9-93
Changed Parameters (4)
9-94
Changed Parameters (5)
9-99
Profibus Revision Counter
5.1.14 12-** Ethernet
Par. No. #
Parameter description
12-0* IP Settings
12-00
IP Address Assignment
12-01
IP Address
12-02
Subnet Mask
12-03
Default Gateway
12-04
DHCP Server
12-05
Lease Expires
12-06
Name Servers
12-07
Domain Name
12-08
Host Name
12-09
Physical Address
12-1* Ethernet Link Parameters
12-10
Link Status
12-11
Link Duration
12-12
Auto Negotiation
12-13
Link Speed
12-14
Link Duplex
12-8* Other Ethernet Services
12-80
FTP Server
12-81
HTTP Server
12-82
SMTP Service
12-89
Transparent Socket Channel Port
12-9* Advanced Ethernet Services
12-90
Cable Diagnostic
12-91
Auto Cross Over
12-92
IGMP Snooping
12-93
Cable Error Length
12-94
Broadcast Storm Protection
MG06C402
Programming Guide
[255] No baudrate found
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[9] Active Set-up
1 set-up
[0] Off
All set-ups
[0] No action
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4-set-up
[10] DCP
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
All set-ups
0 N/A
0 N/A
0 N/A
0 N/A
[0] No Link
All set-ups
ExpressionLimit
All set-ups
[1] On
[0] None
[1] Full Duplex
[0] Disabled
[0] Disabled
[0] Disabled
4000 N/A
[0] Disabled
[1] Enabled
[1] Enabled
0 N/A
-1 %
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
Change
Conver-
during
sion index
operation
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
-
Uint8
0
Uint16
0
OctStr[0]
0
V2
0
V2
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
5
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
Type
-
Uint8
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
TimD
0
OctStr[4]
0
VisStr[48]
0
VisStr[48]
0
VisStr[17]
-
Uint8
0
TimD
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Int8
123
5