Parameter Descriptions
5-55 Term. 33 Low Frequency
Range:
Function:
reference value) in parameter 5-57 Term. 33
Low Ref./Feedb. Value.
5-56 Term. 33 High Frequency
Range:
Function:
32000 Hz
[5 - 32000
Enter the high frequency corresponding
*
Hz]
to the high motor shaft speed (i.e. high
reference value) in parameter 5-58 Term.
33 High Ref./Feedb. Value.
5-57 Term. 33 Low Ref./Feedb. Value
Range:
Function:
0
[-4999 -
Enter the low reference value [Hz] for the
*
4999 ]
motor shaft speed. This is also the low
feedback value, see also parameter 5-52 Term.
29 Low Ref./Feedb. Value.
5-58 Term. 33 High Ref./Feedb. Value
Range:
Function:
Size related
[-4999 -
Enter the high reference value [Hz]
*
4999 ]
for the motor shaft speed. See also
parameter 5-53 Term. 29 High Ref./
Feedb. Value.
4.6.6 5-6* Pulse Outputs
NOTICE
These parameters cannot be adjusted while the motor is
running.
Use these parameters to configure pulse outputs with their
functions and scaling. Terminal 27 and 29 are allocated to
pulse output via 5-01 Terminal 27 Mode and 5-02 Terminal
29 Mode.
Output value
High output
value
P 5-60(term27)
P 5-63(term29)
Illustration 4.14 Configuration of Pulse Outputs
MG06C402
Programming Guide
High freq.
Output
P 5-62(term27)
(Hz)
P 5-65(term29)
Danfoss A/S © Rev. 2014-03-31 All rights reserved.
5-60 Terminal 27 Pulse Output Variable
Option:
[0]
No operation
*
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100]
Output frequency
[101]
Reference
[102]
Process Feedback
[103]
Motor Current
[104]
Torque rel to limit
[105]
Torq relate to rated
[106]
Power
[107]
Speed
[109]
Max Out Freq
5-62 Pulse Output Max Freq 27
Range:
Function:
5000 Hz
[4 - 32000
Set the maximum frequency for terminal
*
Hz]
27, corresponding to the output variable
selected in parameter 5-60 Terminal 27
Pulse Output Variable.
5-63 Terminal 29 Pulse Output Variable
Option:
[0]
No operation
*
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100]
Output frequency
[101]
Reference
[102]
Process Feedback
[103]
Motor Current
[104]
Torque rel to limit
[105]
Torq relate to rated
[106]
Power
[107]
Speed
[109]
Max Out Freq
5-65 Pulse Output Max Freq 29
Range:
Function:
5000 Hz
[4 - 32000
Set the maximum frequency for terminal
*
Hz]
29 corresponding to the output variable
set in parameter 5-63 Terminal 29 Pulse
Output Variable.
4.6.7 5-7* 24 V Encoder Input
Connect the 24 V encoder to terminal 12 (24 V DC supply),
terminal 32 (Channel A), terminal 33 (Channel B), and
terminal 20 (GND). The digital inputs 32/33 are active for
encoder inputs when [1] 24 V encoder is selected in
parameter 7-00 Speed PID Feedback Source. The encoder
used is a dual channel (A and B) 24 V type. Maximum
input frequency: 32 kHz.
Function: