Expansion valve: Removal - Refitting
F4R, and AIR CONDITIONING 01 or AIR CONDITIONING 02
a Position the second threaded rod (7) M5 X 80 length
= 80 mm in place of the bolt (6) .
a Remove:
- the expansion valve,
- the seals (8) of the refrigerant connecting pipes.
AIR CONDITIONING
122571
122572
62A-36
REFITTING
I - REFITTING PREPARATION OPERATION
a
WARNING
Do not remove the blanking plugs from each
component until the last moment.
Also, do not remove the components from their
packaging until they are to be fitted to the vehi-
cle.
Always replace:
- the expansion valve each time it is removed (after-
sales part kit),
- the new expansion valve connecting pipe seals.
62A