Hmi And Basic Programming; Use Of The Hmi To Operate The Inverter - WEG CFW501 V1.8X Programming Manual

Frequency inverter
Table of Contents

Advertisement

4 HMI AND BASIC PROGRAMMING

4.1 USE OF THE HMI TO OPERATE THE INVERTER

Through the HMI, it is possible to view and set all the parameters. The HMI features two operating modes: monitoring
and parameterization. The functions of the keys and the active fields on the HMI display vary according to the
operating mode. The setting mode is composed of three levels.
- When in the setting mode, level 1:
press this key to return to the
monitoring mode.
- When in the setting mode, level 2:
press this key to return to level 1 of
the setting mode.
- When in the setting mode, level 3:
press this key to cancel the new value
(new value is not saved) and return to
level 2 of the setting mode.
- When in the monitoring mode: press
this key to increase the speed.
- When in the setting mode, level 1:
press this key to go to the previous
group.
- When in the setting mode, level 2:
press this key to go to the next
parameter.
- When in the setting mode, level 3:
press this key to increase the content
of the parameter.
Press this key to define the motor
rotation direction.
Active when:
P0223 = 2 or 3 in LOC and/or
P0226 = 2 or 3 in REM.
Press this key to commute between
LOCAL and REMOTE mode.
Active when:
P0220 = 2 or 3.
Press this key to accelerate the motor up to the speed set in P0122 within the time determined
by the acceleration ramp. The motor speed is kept while the key is pressed. When the key is
released, the motor decelerates within the time determined by the deceleration ramp, until it
stops. This function is active when all the conditions below are met:
1. Run/stop = Stop;
2. General enable = Active;
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
HMI and Basic Programming
- When in the monitoring mode: press this key to
enter the setting mode.
- When in the setting mode, level 1: press this key
to select the desired parameter group – it shows
the parameter group selected.
- When in the setting mode, level 2: press this key
to show the parameter- It shows the content of
the parameter to change the content.
- When in the setting mode, level 3: press this
key to save the new content of the parameter – it
returns to level 2 of the setting mode.
- When in the monitoring mode: press this key to
decrease the speed.
- When in the setting mode, level 1: press this key
to go to the next group.
- When in the setting mode, level 2: press this key
to show the previous parameter.
- When in the setting mode, level 3: press this key
to decrease the content of the parameter.
Press this key to accelerate the motor within the
time determined by the acceleration ramp.
Active when:
P0224 = 0 in LOC or
P0227 = 0 in REM.
Press this key to decelerate the motor within the
time determined by the deceleration ramp.
Active when:
P0224 = 0 in LOC or
P0227 = 0 in REM.
Figure 4.1: HMI Keys
4
CFW501 | 4-1

Hide quick links:

Advertisement

Table of Contents
loading