WEG CFW501 V1.8X Programming Manual page 113

Frequency inverter
Table of Contents

Advertisement

P0235 – Input Filter AI1
P0240 – Input Filter AI2
P0245 – Input Filter AI3
Adjustable
0.00 to 16.00 s
Range:
Properties:
Access groups
I/O
via HMI:
Description:
Each analog input of the inverter is defined by the steps of calculation of signal, OFFSET, gain, filter, function and
value AIx, as shown in
Figure 12.2: Block diagram of the analog inputs – Aix on page
Input
AI1
(*)
AI2
(*)
AI3
(*)
Signal
AI1 – P0233
AI2 – P0238
AI3 – P0243
AI1 – P0234
AI2 – P0239
AI3 – P0244
(*) Control terminals available in the Plug-in module.
P0233 – Input Signal AI1
P0238 – Input Signal AI2
Adjustable
0 = 0 to 10 V / 20 mA
Range:
1 = 4 to 20 mA
2 = 10 V / 20 mA to 0
3 = 20 to 4 mA
Properties:
cfg
Access groups
I/O
via HMI:
Gain
AI1 – P0232
AI2 – P0237
AI3 – P0242
OFFSET
Figure 12.2: Block diagram of the analog inputs – Aix
Digital and Analog Inputs and Outputs
Factory
Setting:
12-5.
AI1 – P0018
AI2 – P0019
AI3 – P0020
Filter
AI1 – P0235
AI2 – P0240
AI3 – P0245
Factory
Setting:
0.15 s
Function
AI1 – P0231
AI2 – P0236
AI3 – P0241
Value AIx
(internal)
0
CFW501 | 12-5
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents