WEG CFW501 V1.8X Programming Manual page 16

Frequency inverter
Table of Contents

Advertisement

Quick Reference of Parameters, Alarms and Faults
0
Param.
Function
P0269 DI7 Function
P0270 DI8 Function
P0271 DI1 Function
P0275 DO1 Function
P0276 DO2 Function
P0277 DO3 Function
P0278 DO4 Function
P0279 DO5 Function
P0281 Fx Frequency
P0282 Fx Hysteresis
P0287 Nx/Ny Hysteresis
P0288 Nx Speed
0-8 | CFW501
Adjustable Range
See options in P0263
See options in P0263
0 = (DI1..DI8)NPN
1 = DI1 PNP
2 = (DI1..DI2)PNP
3 = (DI1..DI3)PNP
4 = (DI1..DI4)PNP
5 = (DI1..DI5)PNP
6 = (DI1..DI6)PNP
7 = (DI1..DI7)PNP
8 = (DI1..DI8)PNP
0 = Not Used
1 = N* > Nx
2 = N > Nx
3 = N < Nx
4 = N = N*
5 = Zero Speed
6 = Is > Ix
7 = Is < Ix
8 = Torque > Tx
9 = Torque < Tx
10 = Remote
11 = Run
12 = Ready
13 = No Fault
14 = No F070
15 = Not Used
16 = No F0021/22
17 = No F0051
18 = No F072
19 = 4-20 mA OK
20 = P0695 Value
21 = Forward
22 = Ride-Through
23 = Pre-Charge OK
24 = Fault
25 = Time Enable > Hx
26 = SoftPLC
27 = Not Used
28 = F > Fx(1)
29 = F > Fx(2)
30 = Not Used
31 = Not Used
32 = No Alarm
33 = No Fault/Alarm
34 = Dry Pump Alarm/Fault
35 = Broken Belt Alarm/Fault
36 = Filter Mainten. Alarm/Fault
37 = Sleep Mode
38 = Not Used
39 = Drive Bypass Contactor
40 = Mains Bypass Contactor
41 = Fire Mode
42 = Self-tunning
See options in P0275
See options in P0275
See options in P0275
See options in P0275
0.0 to 500.0 Hz
0.0 to 15.0 Hz
0 to 900 rpm
0 to 18000 rpm
User
Factory Setting
Propr.
Setting
0
cfg
0
cfg
0
cfg
11
0
24
0
0
4.0 Hz
2.0 Hz
18 (15) rpm
120 (100) rpm
Groups
Pag.
I/O
12-17
I/O
12-17
I/O
12-15
I/O
12-22
I/O
12-22
I/O
12-22
I/O
12-22
I/O
12-22
I/O
12-24
I/O
12-24
I/O
12-24
I/O
12-24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents