Set it according to the value informed on the motor nameplate.
It affects the motor overload protection.
P0399 – Motor Rated Efficiency
Adjustable
50.0 to 99.9 %
Range:
Properties:
cfg, V V W
Access groups
MOTOR, STARTUP
via HMI:
Description:
This parameter is important for the precise operation of the VVW control. The imprecise setting will cause the
incorrect calculation of the slip compensation and consequent speed control imprecision.
P0400 – Motor Rated Voltage
Adjustable
200 to 600 V
Range:
Properties:
cfg
Access groups
MOTOR, STARTUP
via HMI:
Description:
Set according to the data on the motor nameplate and the wire connection on the motor terminal box. This
value cannot be above the rated voltage value set in P0296 (power supply rated voltage).
NOTE!
In order to validate a new setting of P0400 out of the HMI "STARTUP" menu, it's necessary to power
cycle the inverter.
Table 10.2: Default setting of P0400 according to the identified inverter model
For further information on model identification, refer to
frames A, B, C, D and E on page
P0296
P0145 (Hz)
50.0
0
60.0
50.0
1
60.0
50.0
2
60.0
Table 6.2: Identification of the CFW501 models for
6-2.
V V W Vector Control
Factory
Setting:
Factory
According to
Setting:
10.2: Default setting
of P0400 according
to the identified
inverter model on
page 10-5
P0400 (V)
230
220
400
380
525
575
75.0 %
Table
10
CFW501 | 10-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents