Quick Reference Of Parameters, Alarms And Faults - WEG CFW501 V1.8X Programming Manual

Frequency inverter
Table of Contents

Advertisement

Quick Reference of Parameters, Alarms and Faults

0
Param.
Function
P0029 Power HW Config.
P0030 Heatsink Temperature
P0037 Motor Overload Ixt
P0042 Powered Time
P0043 Enabled Time
P0044 kWh Output Energy
P0047 CONF State
P0048 Present Alarm
P0049 Present Fault
P0050 Last Fault
P0051 Current At Last Fault
P0052 DC Link At Last Fault
P0053 Frequency At Last Fault
P0054 Temp. At Last Fault
P0055 Log. State Last Fault
P0060 Second Fault
P0061 Current at 2
nd
P0062 DC Link at 2
nd
P0063 Frequency 2
nd
P0064 Temp. 2
Fault
nd
P0065 Log. State 2
nd
P0070 Third Fault
P0071 Current at 3
Fault
rd
P0072 DC Link 3
Fault
rd
P0073 Frequency 3
rd
P0074 Temp. 3
Fault
rd
0-2 | CFW501
Adjustable Range
0 = Not Identified
1 = 200-240 V / 1.6 A
2 = 200-240 V / 2.6 A
3 = 200-240 V / 4.3 A
4 = 200-240 V / 7.0 A
5 = 200-240 V / 9.6 A
6 = 380-480 V / 1.0 A
7 = 380-480 V / 1.6 A
8 = 380-480 V / 2.6 A
9 = 380-480 V / 4.3 A
10 = 380-480 V / 6.1 A
11 = 200-240 V / 7.3 A
12 = 200-240 V / 10.0 A
13 = 200-240 V / 16.0 A
14 = 380-480 V / 2.6 A
15 = 380-480 V / 4.3 A
16 = 380-480 V / 6.5 A
17 = 380-480 V / 10.0 A
18 = 200-240 V / 24.0 A
19 = 380-480 V / 14.0 A
20 = 380-480 V / 16.0 A
21 = 500-600 V / 1.7 A
22 = 500-600 V / 3.0 A
23 = 500-600 V / 4.3 A
24 = 500-600 V / 7.0 A
25 = 500-600 V / 10.0 A
26 = 500-600 V / 12.0 A
27 = 200-240 V / 28.0 A
28 = 200-240 V / 33.0 A
29 = 380-480 V / 24.0 A
30 = 380-480 V / 31.0 A
31 = 500-600 V / 17.0 A
32 = 500-600 V / 22.0 A
33 = 200-240 V / 47.0 A
34 = 200-240 V / 56.0 A
35 = 380-480 V / 39.0 A
36 = 380-480 V / 49.0 A
37 = 500-600 V / 27.0 A
38 = 500-600 V / 32.0 A
-20 to 150 ºC
0 to 100 %
0 to 65535 h
0.0 to 6553.5 h
0 to 65535 kWh
0 to 999
0 to 999
0 to 999
0 to 999
0.0 to 200.0 A
0 to 2000 V
0.0 to 500.0 Hz
-20 to 150 ºC
0000h to FFFFh
0 to 999
Fault
0.0 to 200.0 A
Fault
0 to 2000 V
Fault
0.0 to 500.0 Hz
-20 to 150 ºC
Fault
0000h to FFFFh
0 to 999
0.0 to 200.0 A
0 to 2000 V
Fault
0.0 to 500.0 Hz
-20 to 150 ºC
User
Factory Setting
Propr.
Setting
Groups
Pag.
ro
READ
6-2
ro
READ
15-5
ro
READ
14-3
ro
READ
15-5
ro
READ
15-5
ro
READ
15-6
ro
READ
15-6
ro
READ
14-8
ro
READ
14-8
ro
READ
14-8
ro
READ
14-9
ro
READ
14-9
ro
READ
14-9
ro
READ
14-10
ro
READ
14-10
ro
READ
14-8
ro
READ
14-9
ro
READ
14-9
ro
READ
14-9
ro
READ
14-10
ro
READ
14-10
ro
READ
14-8
ro
READ
14-9
ro
READ
14-9
ro
READ
14-9
ro
READ
14-10

Hide quick links: