Param.
Function
P0075 Log. State 3
Fault
rd
P0080 Last Fault in "Fire Mode"
P0081 Second Fault in "Fire Mode"
P0082 Third Fault in "Fire Mode"
P0100 Acceleration Time
P0101 Deceleration Time
P0102 2
Ramp Accel. Time
nd
P0103 2
Ramp Decel. Time
nd
P0104 S Ramp
P0105 1
/2
Ramp Sel.
st
nd
P0106 3
Ramp Time
rd
P0120 Speed Ref. Backup
P0121 Keypad Reference
P0122 JOG Reference
P0133 Minimum Speed
P0134 Maximum Speed
P0135 Max. Output Current
P0136 Manual Torque Boost
P0137 Autom. Torque Boost
P0138 Slip Compensation
P0139 Output Current Filter
P0140 Sleep Compensation Filter
P0142 Max. Output Voltage
P0143 Interm.Output Voltage
P0144 Low Output Voltage
P0145 Field Weakening Speed
P0146 Intermediate Speed
P0147 Low Speed point
P0150 Ud Regul. Type V/f and Current
Limitation
P0151 DC Regul. Level V/f
P0152 DC Link Regul. P Gain
P0153 Dyn. Braking Level
P0156 Overl.Curr. 100 % Speed
P0157 Overl.Curr. 50 % Speed
P0158 Overl.Curr. 20 % Speed
P0178 Rated Flux
P0200 Password
P0202 Type of Control
Quick Reference of Parameters, Alarms and Faults
Adjustable Range
0000h to FFFFh
0 to 999
0 to 999
0 to 999
0.1 to 999.0 s
0.1 to 999.0 s
0.1 to 999.0 s
0.1 to 999.0 s
0 = Inactive
1 = Active
0 = 1
Ramp
st
1 = 2
Ramp
nd
2 = DIx
3 = Serial/USB
4 = SoftPLC
0.1 to 999.0 s
0 = Inactive
1 = Active
2 = Backup by P0121
0 to 18000 rpm
0 to 18000 rpm
0 to 18000 rpm
0 to 18000 rpm
0.0 to 200.0 A
0.0 to 30.0 %
0.0 to 30.0 %
-10.0 to 10.0 %
0 to 9999 ms
0 to 9999 ms
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0 to 18000 rpm
0 to 18000 rpm
0 to 18000 rpm
0 = hold_Ud and desac_LC
1 = acel_Ud and desac_LC
2 = hold_Ud and hold_LC
3 = acel_Ud and hold_LC
339 to 1200 V
0.00 to 9.99
339 to 1200 V
0.0 to 200.0 A
0.0 to 200.0 A
0.0 to 200.0 A
0.0 to 150.0 %
0 = Inactive
1 = Active
1 to 19999 = New password
0 to 2 = V/f
3 = V V W
User
Factory Setting
Propr.
Setting
0
0
0
10.0 s
10.0 s
10.0 s
10.0 s
0
2
5.0 s
1
90 rpm
150 (125) rpm
90 (75) rpm
1800 (1500) rpm
1.5xI
V/f, V V W
nom
According to
inverter model
0.0 %
0.0 %
50 ms
500 ms
V V W
100.0 %
cfg, V/f
66.7 %
cfg, V/f
33.3 %
cfg, V/f
1800 (1500) rpm
cfg, V/f
1200 (1000) rpm
cfg, V/f
600 (500) rpm
cfg, V/f
0
cfg, V/f,
V V W
400 V (P0296 = 0)
V/f, V V W MOTOR
800 V (P0296 = 1)
1000 V (P0296 = 2)
1.50
V/f, V V W MOTOR
375 V (P0296 = 0)
V/f, V V W MOTOR
750 V (P0296 = 1)
950 V (P0296 = 2)
1.1xI
nom
1.0xI
nom
0.8xI
nom
100.0 %
0
0
0
0
Groups
Pag.
ro
READ
14-10
ro
READ
14-10
ro
READ
14-10
ro
READ
14-10
BASIC
11-1
BASIC
11-1
11-2
11-2
cfg
11-2
I/O
11-3
11-3
7-8
7-9
7-9
BASIC
7-8
BASIC
7-8
BASIC,
11-8
MOTOR
V/f
BASIC,
9-4
MOTOR
V/f
MOTOR
9-6
V/f
MOTOR
9-7
8-1
8-2
9-5
9-5
9-5
9-5
9-5
9-5
MOTOR
11-4
11-5
11-5
13-1
MOTOR
14-2
MOTOR
14-2
MOTOR
14-2
MOTOR
10-4
HMI
5-3
cfg
STARTUP
8-1
CFW501 | 0-3

Hide quick links: