Signal - Mitsubishi Electric MELSERVO-J4 Series Instruction Manual

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

Signal

Connector/pin assignment
■CN8A
Device
Symbol
A-axis STO1
STO1A-
STO1A+
A-axis STO2
STO2A-
STO2A+
A-axis STO state
TOF2A
TOF1A
■CN8B
Device
Symbol
B-axis STO1
STO1B-
STO1B+
B-axis STO2
STO2B-
STO2B+
B-axis STO state
TOF2B
TOF1B
■CN9
Device
Symbol
A-axis shutdown 1
SDI1A+
SDI1A-
B-axis shutdown 1
SDI1B+
SDI1B-
A-axis SDO1
SDO1A+
SDO1A-
B-axis SDO1
SDO1B+
SDO1B-
■CN10
Device
Symbol
A-axis shutdown 2
SDI2A+
SDI2A-
APPX
592
Appendix 5 MR-J3-D05 Safety logic unit
Pin No.
Function/application
1
Outputs STO1 to A-axis driving device.
4
Outputs the same signal as A-axis STO2.
STO state (base shutdown): Between STO1A+ and STO1A- is opened.
STO release state (in driving): Between STO1A+ and STO1A- is closed.
5
Outputs STO2 to A-axis driving device.
6
Outputs the same signal as A-axis STO1.
STO state (base shutdown): Between STO2A+ and STO2A- is opened.
STO release state (in driving): Between STO2A+ and STO2A- is closed.
7
Inputs STO state of A-axis driving device.
8
STO state (base shutdown): Open between TOF2A and TOF1A.
STO release state (in driving): Close between TOF2A and TOF1A.
Pin No.
Function/application
1
Outputs STO1 to B-axis driving device.
4
Outputs the same signal as B-axis STO2.
STO state (base shutdown): Between STO1B+ and STO1B- is opened.
STO release state (in driving): Between STO1B+ and STO1B- is closed.
5
Outputs STO2 to B-axis driving device.
6
Outputs the same signal as B-axis STO1.
STO state (base shutdown): Between STO2B+ and STO2B- is opened.
STO release state (in driving): Between STO2B+ and STO2B- is closed.
7
Inputs STO state of B-axis driving device.
8
STO state (base shutdown): Open between TOF2B and TOF1B.
STO release state (in driving): Close between TOF2B and TOF1B.
Pin No.
Function/application
1A
Connect this device to a safety switch for A-axis driving device.
1B
Input the same signal as A-axis shutdown 2.
STO state (base shutdown): Open between SDI1A+ and SDI1A-.
STO release state (in driving): Close between SDI1A+ and SDI1A-.
2A
Connect this device to a safety switch for B-axis driving device.
2B
Input the same signal as B-axis shutdown 2.
STO state (base shutdown): Open between SDI1B+ and SDI1B-.
STO release state (in driving): Close between SDI1B+ and SDI1B-.
4A
Outputs STO1 to A-axis driving device.
4B
Outputs the same signal as A-axis SDO2.
STO state (base shutdown): Between SDO1A+ and SDO1A- is opened.
STO release state (in driving): Between SDO1A+ and SDO1A- is closed.
3A
Outputs STO1 to B-axis driving device.
3B
Outputs the same signal as B-axis SDO2.
STO state (base shutdown): Between SDO1B+ and SDO1B- is opened.
STO release state (in driving): Between SDO1B+ and SDO1B- is closed.
Pin No.
Function/application
3A
Connect this device to a safety switch for A-axis driving device.
3B
Input the same signal as A-axis shutdown 1.
STO state (base shutdown): Open between SDI2A+ and SDI2A-.
STO release state (in driving): Close between SDI2A+ and SDI2A-.
I/O
division
O
O
I
I/O
division
O
O
I
I/O
division
DI-1
DI-1
DO-1
DO-1
I/O
division
DI-1