1.6

Model designation

Rating plate
The following shows an example of rating plate for explanation of each item.
SER.A5X001001
MR-J4-10GF
MODEL
POWER :100W
INPUT
: 3AC/AC200-240V 0.9A/1.5A 50/60Hz
OUTPUT: 3PH170V 0-360Hz 1.1A
STD.: IEC/EN 61800-5-1
MAN.: IB(NA)0300175
Max. Surrounding Air Temp.: 55°C
IP20
KCC-REI-MEK-TC301A079G51
DATE:2015-10
TOKYO 100-8310, JAPAN
MADE IN JAPAN
Model
The following describes what each block of a model name indicates. Not all combinations of the symbols are available.
M R
-
J
4
-
6
0 G
Series
Rated output
Symbol Rated output [kW]
10
0.1
20
0.2
40
0.4
60
0.6
70
0.75
100
1
200
2
350
3.5
500
5
700
7
11K
11
15K
15
22K
22
*1 Indicates a servo amplifier of 11 kW to 22 kW that does not use a regenerative resistor as standard accessory.
Page 622 Without regenerative resistor
*2 Dynamic brake which is built in 7 kW or smaller servo amplifiers is removed.
Page 621 Amplifiers without dynamic brake
*3 Type with a specially-coated servo amplifier board (IEC 60721-3-3 Class 3C2).
Page 623 Special coating-specification product (IEC 60721-3-3 Class 3C2)
AC SERVO
Serial number
Model
Capacity
Applicable power supply
Rated output current
Standard, Manual number
Ambient temperature
IP rating
KC certification number, The year and month of manufacture
Country of origin
F
4
-
R
J
Special specifications
Symbol
None Standard
Fully closed loop control four-wire type/load-side encoder
-RJ
A/B/Z-phase input compatible
-ED
MR-J4-_GF_ without a dynamic brake
-RU
MR-J4-_GF_-RJ without a dynamic brake
-PX
MR-J4-_GF_ without regenerative resistor
-RZ
MR-J4-_GF_-RJ without regenerative resistor
-EB
MR-J4-_GF_ with a special coating specification (3C2)
-KS
MR-J4-_GF_-RJ with a special coating specification (3C2)
Power supply
Symbol
None 3-phase or 1-phase
200 V AC to 240 V AC
1
1-phase 100 V AC to 120 V AC
4
3-phase 380 V AC to 480 V AC
CC-Link IE Field Network
Special specifications
*2
Power supply
1 FUNCTIONS AND CONFIGURATION
*2
*1
*1
*3
*3
1.6 Model designation
1
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents