3. SIGNALS AND WIRING

3.2 Connectors and signal layouts of the servo amplifiers

3.2.1 MELSERVO-J2-Super series

(1) MR-J2S- A/A4
CN1A
Same as the one of
the MR-J2S-11KA to 22KA.
CN1B
Same as the one of
the MR-J2S-11KA to 22KA.
11
12
13
14
BAT
15
16
LG
P5
17
18
LG
19
20
SD
The MR-HCN2 is mounted.
Downloaded from
ManualsNet.com
POINT
The signals are the same as those of the 11k to 22kW servo amplifiers.
Refer to the Signal chapter of the corresponding Servo Amplifier
Instruction Manual.
The pin layouts of the connectors are as seen from the connector wiring
section of the cable.
TE2-1
CN2
1
2
LG
LG
3
4
MRR
MR
5
6
The connector frames are connected to
7
the PE (earth) terminal in the amplifier.
8
P5
P5
9
10
search engine
CN4
1
2
4
TE2-2
Charge lamp
C
N
3
C
N
1
A
C
N
1
B
TE3
CN5A
CON2
CN5B
CN2
TE1
3 - 4
CN3
1
2
LG
MO1
RXD
TXD
3
MO2
4
5
LG
6
LA
LAR
7
8
LB
LZ
LZR
9
10
CN4
CON2
1
2
LG
AN1
3
4
BAT
5
6
SD
SR
SSR
7
LG
11
12
LG
13
14
15
16
17
18
LBR
19
20
8
9
AN0
10
11
SDR
12
13
SDR
14
LG

Advertisement