Parameter
Set [Pr. PB45 Command notch filter] as shown below. For the command notch filter setting frequency, set the closest value to
the vibration frequency [Hz] at the load side.
[Pr. PB45]
0
Notch depth
Depth
Setting
[dB]
value
0
-40.0
-24.1
1
2
-18.1
3
-14.5
-12.0
4
5
-10.1
6
-8.5
-7.2
7
8
-6.0
9
-5.0
A
-4.1
B
-3.3
C
-2.5
D
-1.8
-1.2
E
F
-0.6
7 SPECIAL ADJUSTMENT FUNCTIONS
258
7.1 Filter setting
Command notch filter setting frequency
Setting
Setting
Frequency
Frequency
[Hz]
value
value
00
Disabled
20
01
2250
21
02
1125
22
03
750
23
04
562
24
05
450
25
06
375
26
07
321
27
08
281
28
09
250
29
0A
225
2A
0B
204
2B
0C
187
2C
0D
173
2D
0E
160
2E
0F
150
2F
10
140
30
11
132
31
12
125
32
13
118
33
14
112
34
15
107
35
16
102
36
17
97
37
18
93
38
19
90
39
1A
86
3A
1B
83
3B
1C
80
3C
1D
77
3D
1E
75
3E
1F
72
3F
Setting
Frequency
[Hz]
[Hz]
value
70
40
17.6
66
41
16.5
62
42
15.6
59
43
14.8
56
44
14.1
53
45
13.4
51
46
12.8
48
47
12.2
46
48
11.7
45
49
11.3
43
4A
10.8
41
4B
10.4
40
4C
10.0
38
4D
9.7
37
4E
9.4
36
4F
9.1
35.2
50
8.8
33.1
51
8.3
31.3
52
7.8
29.6
53
7.4
28.1
54
7.0
26.8
55
6.7
25.6
56
6.4
24.5
57
6.1
23.4
58
5.9
22.5
59
5.6
21.6
5A
5.4
20.8
5B
5.2
20.1
5C
5.0
19.4
5D
4.9
18.8
5E
4.7
18.2
5F
4.5