Relay (Recommended) - Mitsubishi Electric MELSERVO-J4 Series Instruction Manual

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

180
W1
W ± 0.5
Servo amplifier
Power factor
improving
AC reactor
MR-J4-15KGF4(-RJ)
FR-HAL-H22K
MR-J4-22KGF4(-RJ)
FR-HAL-H30K
*1 Use this for grounding.
*2 Maximum dimensions. The dimension varies depending on the input/output lines.
11.13

Relay (recommended)

The following relays should be used with the interfaces.
Interface
Digital input (interface DI-1)
Relay used for digital input command signals
Digital output (interface DO-1)
Relay used for digital output signals
11.14
Noise reduction techniques
Noises are classified into external noises which enter the servo amplifier to cause it to malfunction and those radiated by the
servo amplifier to cause peripheral equipment to malfunction. Since the servo amplifier is an electronic device which handles
small signals, the following general noise reduction techniques are required.
Also, the servo amplifier can be a source of noise as its outputs are chopped by high carrier frequencies. If peripheral
equipment malfunctions due to noises produced by the servo amplifier, noise suppression measures must be taken. The
measures will vary slightly with the routes of noise transmission.
Noise reduction techniques
■General reduction techniques
• Avoid bundling power lines (input/output) and signal cables together or running them in parallel to each other. Separate the
power lines from the signal cables.
• Use a shielded twisted pair cable for connection with the encoder and for control signal transmission, and connect the
external conductor of the cable to the SD terminal.
• Ground the servo amplifier, servo motor, etc. together at one point. Page 126 Grounding
11 OPTIONS AND PERIPHERAL EQUIPMENT
416
11.13 Relay (recommended)
R X S
Y T
Z
*1
4-d mounting hole
( 8 groove)
D or less
D2
D1
Dimensions [mm]
W
W1
H
220
200
215
220
200
215
MCCB
3-phase
380 V AC to
480 V AC
*2
D
D1
D2
170
90
70
170
96
75
Selection example
To prevent defective contacts, use a relay for small signal (twin contacts).
(Ex.) Omron: type G2A, MY
Small relay with 12 V DC or 24 V DC of rated current 40 mA or less
(Ex.) Omron: type MY
Servo amplifier
3-phase
400 V class
FR-HAL-H
MC
R
X
L1
S
Y
L2
T
Z
L3
Terminal
Mass [kg]
size
d
M5
M8
9.5
M5
M8
11