■Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. This function is used for output signal wiring
check, etc. Perform on the DO forced output screen of MR Configurator2.
■Program operation
Positioning operation can be performed in two or more operation patterns combined, without using the controller. Use this
operation with the forced stop reset. This operation may be used independently of whether the servo is on or off and whether
the controller is connected or not.
Perform on the program operation screen of MR Configurator2. For full information, refer to Help of MR Configurator2.
Operation
Start
Pause
Stop
Forced stop
Operation procedure
1.
Turn off the power.
2.
Turn "ON (up)" SW1-1.
ON
1
2
Turning "ON (up)" SW1-1 during power-on will not enable the test operation mode.
3.
Turn on the servo amplifier.
When initialization is completed, the display shows the following screen.
After 1.6 s
Blinking
After 0.2 s
4.
Start operation with the personal computer.
Screen control
Click "Operation start".
Click "Pause".
Click "Stop".
Click "Forced stop".
ON
1
2
Set SW1-1 to "ON (up)".
14 USING A LINEAR SERVO MOTOR
14.3 Operation and functions
14
485