Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 193

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

No./symbol/
Setting
Function
name
digit
PA21
_ _ _ x
One-touch tuning function selection
*AOP3
0: Disabled
Function selection
1: Enabled
A-3
When the digit is "0", the one-touch tuning with MR Configurator2 will be disabled.
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
PA22
_ _ _ x
For manufacturer setting
**PCS
_ _ x _
Super trace control selection
Position control
0: Disabled
composition
2: Enabled
selection
_ x _ _
For manufacturer setting
x _ _ _
Scale measurement function selection
0: Disabled
1: Used in absolute position detection system
2: Used in incremental system
The absolute position detection system cannot be used while an incremental type encoder is used. Enabling
absolute position detection system will trigger [AL. 37 Parameter error].
Additionally, the setting is enabled only in the standard control mode. Setting other than "0" in other operation
modes triggers [AL. 37 Parameter error].
The setting of this digit is used by servo amplifier with software version A1 or later.
PA23
_ _ x x
Alarm detail No. setting
DRAT
Set the digits when you execute the trigger with arbitrary alarm detail No. for the drive recorder function.
Drive recorder
When these digits are "0 0", only the arbitrary alarm No. setting will be enabled.
arbitrary alarm
x x _ _
Alarm No. setting
trigger setting
Set the digits when you execute the trigger with arbitrary alarm No. for the drive recorder function.
When "0 0" are set, arbitrary alarm trigger of the drive recorder will be disabled.
Setting example:
To activate the drive recorder when [AL. 50 Overload 1] occurs, set "5 0 0 0".
To activate the drive recorder when [AL. 50.3 Thermal overload error 4 during operation] occurs, set "5 0 0 3".
PA24
_ _ _ x
Vibration suppression mode selection
AOP4
0: Standard mode
Function selection
1: 3 inertia mode
A-4
2: Low response mode
When you select the standard mode or low response mode, "Vibration suppression control 2" is not available.
When you select the 3 inertia mode, the feed forward gain is not available.
Before changing the control mode during the 3 inertia mode or low response mode, stop the motor.
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
PA25
Set a permissible value of overshoot amount for one-touch tuning as a percentage of the in-position range.
OTHOV
Note that setting "0" will be 50%.
One-touch tuning -
Setting range: 0 to 100
Overshoot
permissible level
PA26
_ _ _ x
Torque limit function selection at instantaneous power failure
*AOP5
0: Disabled
Function selection
1: Enabled
A-5
When an instantaneous power failure occurs during operation, you can save electric energy charged in the
capacitor in the servo amplifier by limiting torque at acceleration. You can also delay the time until [AL. 10.2
Voltage drop in the main circuit power] occurs with instantaneous power failure tough drive function. Doing
this will enable you to set a longer time in [Pr. PF25 SEMI-F47 function - Instantaneous power failure
detection time].
The torque limit function at instantaneous power failure is enabled when "SEMI-F47 function selection" in [Pr.
PA20] is "Enabled (_ 1 _ _)".
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
Initial
value
[unit]
1h
0h
0h
0h
0h
0h
0h
0h
00h
00h
0h
0h
0h
0h
0 [%]
0h
0h
0h
0h
5 PARAMETERS
5.2 Detailed list of parameters
5
191