PA16
*ENR2
Encoder output
pulses 2
5 PARAMETERS
188
5.2 Detailed list of parameters
Function
Set a denominator of the electronic gear for the A/B-phase pulse output.
Set a denominator of the electronic gear when selecting "A-phase/B-phase pulse electronic gear setting (_ _
3 _)" of "Encoder output pulse setting selection" in [Pr. PC03].
Refer to the following for details.
Page 635 Encoder output pulse setting methodThe maximum output frequency is 4.6 Mpulses/s. Set the
parameter within this range.
Selecting "Dividing ratio setting (_ _ 1 _)" of "Encoder output pulse setting selection" in [Pr. PC03] will disable
the setting value.
Setting range: 1 to 4194304
Initial
value
[unit]
1