11.6
Junction terminal block PS7DW-20V14B-F
(recommended)
Usage
Always use the junction terminal block (PS7DW-20V14B-F (Toho Technology Corp. Kyoto factory)) with the option cable (MR-
J2HBUS_M) as a set. A connection example is shown below.
Servo amplifier
Cable clamp
(AERSBAN-ESET)
CN3
MR-J2HBUS_M
Ground the option cable on the junction terminal block side with the cable clamp fitting (AERSBAN-ESET). For the use of the
cable clamp fitting, refer to the following.
Page 421 Cable clamp fitting AERSBAN-_SET
Connection of MR-J2HBUS_M cable and junction terminal block
Servo amplifier
CN3
MR-J2HBUS_M
TPR2
1
1
LSP
2
2
DOCOM
3
3
MO1
4
4
DICOM
5
5
LA
6
6
LB
7
7
LZ
8
8
INP
9
9
TPR1
10
10
LG
11
11
LSN
12
12
MBR
13
13
MO2
14
14
ALM
15
15
LAR
16
16
LBR
17
17
LZR
18
18
DOG
19
19
EM2
20
20
SD
Shell
Shell
Connector: 52316-2019 (Molex)
Shell kit: 52370-2070 (Molex)
*1 Symbol indicating cable length is put in _.
05: 0.5 m
1: 1 m
5: 5 m
Junction terminal block
PS7DW-20V14B-F
Junction terminal block
PS7DW-20V14B-F
*1
CN
Terminal block
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
Shell Shell

11.6 Junction terminal block PS7DW-20V14B-F (recommended)

1
TPR2
2
LSP
3
DOCOM
4
MO1
5
DICOM
6
LA
7
LB
8
LZ
9
INP
10
TPR1
11
LG
12
LSN
13
MBR
14
MO2
15
ALM
16
LAR
17
LBR
18
LZR
19
DOG
20
EM2
E
SD