[Additional instructions]
The following instructions should also be fully noted. Incorrect handling may cause a malfunction, injury, electric shock, fire,
etc.
[Transportation and installation]
CAUTION
● Transport the products correctly according to their mass.
● Stacking in excess of the specified number of product packages is not allowed.
● Do not hold the front cover, cables, or connectors when carrying the servo amplifier. Otherwise, it may
drop.
● Install the servo amplifier and the servo motor in a load-bearing place in accordance with the
Instruction Manual.
● Do not get on or put heavy load on the equipment. Otherwise, it may cause injury.
● The equipment must be installed in the specified direction.
● Maintain specified clearances between the servo amplifier and the inner surfaces of a control cabinet
or other equipment.
● Do not install or operate the servo amplifier and servo motor which have been damaged or have any
parts missing.
● Do not block the intake and exhaust areas of the servo amplifier. Otherwise, it may cause a
malfunction.
● Do not drop or apply heavy impact on the servo amplifiers and the servo motors. Otherwise, it may
cause injury, malfunction, etc.
● Do not strike the connector. Otherwise, it may cause a connection failure, malfunction, etc.
● When you keep or use the equipment, please fulfill the following environment.
Item
Operation
Ambient
temperature
Storage
Operation
Ambient
humidity
Storage
Ambience
Altitude
Vibration resistance
● When the product has been stored for an extended period of time, contact your local sales office.
● When handling the servo motor, be careful with the sharp edges of the servo motor.
● The servo amplifier must be installed in a metal cabinet.
● When fumigants that contain halogen materials, such as fluorine, chlorine, bromine, and iodine, are
used for disinfecting and protecting wooden packaging from insects, they cause a malfunction when
entering our products. Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other than fumigation, such as
heat treatment. Additionally, disinfect and protect wood from insects before packing the products.
● To prevent a fire or injury in case of an earthquake or other natural disasters, securely install, mount,
and wire the servo motor in accordance with the Instruction Manual.
4
5 %RH to 90 %RH (non-condensing)
Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt
2000 m or less above sea level (Contact your local sales office for the altitude for options.)
5.9 m/s
Environment
0 °C to 55 °C (non-freezing)
-20 °C to 65 °C (non-freezing)
2
, at 10 Hz to 55 Hz (X, Y, Z axes)