No./symbol/
Setting
name
digit
PA19
*BLK
Parameter writing
inhibit
PA19
Other than
below
000Ah
000Bh
000Ch
000Fh
00AAh
00ABh
(initial
value)
100Bh
100Ch
100Fh
10AAh
10ABh
PA20
Alarms may not be avoided with the tough drive function depending on the situations of the power supply and load fluctuation.
*TDS
You can assign MTTR (During tough drive) to pins CN3-9, CN3-13, and CN3-15 with [Pr. PD07] to [Pr. PD09].
Tough drive setting
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
5 PARAMETERS
190
5.2 Detailed list of parameters
Function
Select a reference range and writing range of the parameter.
Refer to the following table for settings.
Setting
PA
PB
operation
Reading
Writing
Reading
Only 19
Writing
Only 19
Reading
Writing
Reading
Writing
Reading
Writing
Reading
Writing
Reading
Writing
Reading
Writing
Only 19
Reading
Writing
Only 19
Reading
Writing
Only 19
Reading
Writing
Only 19
Reading
Writing
Only 19
For manufacturer setting
Vibration tough drive selection
0: Disabled
1: Enabled
Selecting "1" enables to suppress vibrations by automatically changing the setting values of [Pr. PB13
Machine resonance suppression filter 1] and [Pr. PB15 Machine resonance suppression filter 2] in case that
the vibration exceeds the value of the oscillation level set in [Pr. PF23].
The parameter will operate when [Pr. PB13 Machine resonance suppression filter 1] and [Pr. PB15 Machine
resonance suppression filter 2] are enabled.
Page 267 Tough drive function
SEMI-F47 function selection
0: Disabled
1: Enabled
Selecting "1" enables to avoid triggering [AL. 10 Undervoltage] using the electrical energy charged in the
capacitor in case that an instantaneous power failure occurs during operation. In [Pr. PF25 SEMI-F47
function - Instantaneous power failure detection time], set the time until the occurrence of [AL. 10.1 Voltage
drop in the control circuit power].
For manufacturer setting
PC
PD
PE
PF
PL
PT
Initial
value
[unit]
00ABh
PN
0h
0h
0h
0h