Extension setting 2 parameters ([Pr. PE_ _ ])

No.
Symbol
Name
PE01
**FCT1
Fully closed loop function selection 1
PE02
For manufacturer setting
PE03
*FCT2
Fully closed loop function selection 2
PE04
**FBN
Fully closed loop control - Feedback pulse electronic gear 1
- Numerator
PE05
**FBD
Fully closed loop control - Feedback pulse electronic gear 1
- Denominator
PE06
BC1
Fully closed loop control - Speed deviation error detection
level
PE07
BC2
Fully closed loop control - Position deviation error detection
level
PE08
DUF
Fully closed loop dual feedback filter
PE09
For manufacturer setting
PE10
FCT3
Fully closed loop function selection 3
PE11
For manufacturer setting
PE12
PE13
PE14
PE15
PE16
PE17
PE18
PE19
PE20
PE21
PE22
PE23
PE24
PE25
PE26
PE27
PE28
PE29
PE30
PE31
PE32
PE33
PE34
**FBN2
Fully closed loop control - Feedback pulse electronic gear 2
- Numerator
PE35
**FBD2
Fully closed loop control - Feedback pulse electronic gear 2
- Denominator
PE36
For manufacturer setting
PE37
PE38
PE39
PE40
PE41
EOP3
Function selection E-3
PE42
For manufacturer setting
PE43
PE44
LMCP
Lost motion compensation positive-side compensation
value selection
Initial
Unit
Operation mode
value
Standard Full.
0000h
0000h
0003h
1
1
400
[r/min]
100
[kpulse]
10
[rad/s]
0000h
0000h
0000h
0000h
0000h
0111h
20
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
1
1
0.0
0.00
0.00
20
0000h
0000h
0
0.0
0
[0.01%]
Lin.
DD
5
5 PARAMETERS